Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0041644 |
Liberty Bulk Transport, Inc. |
Current Owner |
7/20/2025 |
| U0014995 |
Thornton's, Inc. - DO NOT USE THIS OWNER ID |
Former Owner |
7/23/2008 |
| U0002187 |
Burwell Oil Service, Inc. |
Former Owner |
4/1/1992 |
| U0039521 |
Thorntons, LLC |
Former Owner |
1/1/1901 |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Ethanol |
|
CERCLA Substance: |
|
| Status: |
Abandoned in place |
|
CAS Code: |
64-17-5 |
| Regulated Status: |
Non-Regulated |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
2/18/1993 |
|
Abandoned Material: |
|
| Current Age: |
33 |
|
Abandoned Date: |
3/10/2025 |
| Install Date: |
11/23/1992 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/24/1992 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
7/20/2015 |
7/20/2016 |
|
Leak Detect - Piping
|
Sump Sensor |
7/20/2015 |
7/20/2016 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
7/20/2015 |
7/20/2016 |
|
Overfill Prev Device
|
Ball Float Vent Valve |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Double Wall |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Fiberglass Double Wall Owens Corning |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
B-99 |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
64-17-8 |
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
2/18/1993 |
|
Abandoned Material: |
|
| Current Age: |
32 |
|
Abandoned Date: |
|
| Install Date: |
11/23/1992 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/24/1993 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Other Aboveground Piping |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Aboveground |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors With Monitor |
5/14/2026 |
5/14/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
2/14/2025 |
2/14/2028 |
|
Piping
|
Steel Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Double Wall Spill Bucket |
2/14/2025 |
2/14/2028 |
|
Tank
|
Fiberglass Double Wall Owens Corning |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Tank
|
Fiberglass Double Wall Owens Corning
|
Precision Test (Tank)
|
Pass
|
2/14/2025
|
|
Leak Detect - Piping
|
Non-Discriminating Sump Sensor
|
Sensor Functional
|
Pass
|
9/30/2008
|
Tank Number 3
| Capacity: |
1000 |
|
Petroleum Use: |
|
| Product: |
Used Oil |
|
CERCLA Substance: |
|
| Status: |
Does Not Exist |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
2/18/1993 |
|
Abandoned Material: |
|
| Current Age: |
5 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
|
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found