Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5027506
Status: Active
Facility Name: Chapin Fast Stop
Address: 1715 Ore Rd.
Chapin, IL 62628
County: Morgan
Property Parcel: 07-02-401-027
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000791
Green Tag Issue Date: 6/9/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: A&A Chapin, Inc.
Owner Address: 1715 Ore Rd.
Chapin, IL 62628
Owner Status: Current Owner / Operator
Purchase Date: 8/29/2017
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/10/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/9/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038927 A&A Chapin, Inc. Current Owner / Operator 8/29/2017
U0013645 Prairieland FS, Inc. Former Owner / Operator 12/31/2014
U0032502 Rock Enterprises & Services, Inc. Former Owner / Operator 12/24/2003
U0006422 Hannel Oil Company Former Owner / Operator
U0008156 Junction Sales Inc. Former Owner / Operator

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/15/1990 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/16/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/16/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 7/26/2022 7/26/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/7/2024 6/7/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 250 6/7/2024 6/7/2025
Overfill Prev Device Overfill Drop Tube Valve 4/26/2022 4/26/2025
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/26/2022 4/26/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/7/2024



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/15/1990 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/16/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/16/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 7/26/2022 7/26/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/7/2024 6/7/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 250 6/7/2024 6/7/2025
Overfill Prev Device Overfill Drop Tube Valve 4/26/2022 4/26/2025
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/26/2022 4/26/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/7/2024



Tank Number 3

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/15/1990 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/16/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/16/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 7/26/2022 7/26/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/7/2024 6/7/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 250 6/7/2024 6/7/2025
Overfill Prev Device Overfill Drop Tube Valve 4/26/2022 4/26/2025
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/26/2022 4/26/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/7/2024



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/15/1990 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/16/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/16/1990

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 7/26/2022 7/26/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/7/2024 6/7/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 250 6/7/2024 6/7/2025
Overfill Prev Device Overfill Drop Tube Valve 4/26/2022 4/26/2025
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/26/2022 4/26/2025
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 6/7/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found