Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5022064
Status: Active
Facility Name: Gillespie Shell Food Mart
Address: 400 S. Macoupin St. Gillespie, IL 62033
County: Macoupin
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000476
Green Tag Issue Date: 1/9/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Joseph F. Boente Sons, Inc.
Owner Address: 511 West Main Street Carlinville, IL 62626
Owner Status: Current Owner
Purchase Date: 8/24/1990
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/1/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/9/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0007689 Joseph F. Boente Sons, Inc. Current Owner 8/24/1990
U0005034 Fassero Oil Co Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020253304 (Pending)    Issue Date: 12/19/2025    Expiration Date: 2/17/2026    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
8, 9 Annual leak detection certification not completed (Required annually).
Facility Missing copies of Annual Walkthrough Inspection Report.
8, 9 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection).
8, 9 Tank interstitial sensor functional test not accomplished (Required annually).

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
10-0901 8/17/2010 Removal Log 00518-2010REM
97-0838 5/13/1997 Removal Log 0838-97

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
10-0901 Eligible 1/19/2011 1/28/2011 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/17/2010
OSFM First Notify Date: 4/15/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 6/24/2005 6/24/2010
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/16/2010 4/16/2011
Leak Detect - Piping Sump Sensor 4/16/2010 4/16/2011
Leak Detect - Tank Automatic Tank Gauging OPW EECO 1500
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/17/2010
OSFM First Notify Date: 4/15/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 6/24/2005 6/24/2010
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/16/2010 4/16/2011
Leak Detect - Piping Sump Sensor 4/16/2010 4/16/2011
Leak Detect - Tank Automatic Tank Gauging OPW EECO 1500
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/17/2010
OSFM First Notify Date: 4/15/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 6/24/2005 6/24/2010
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/16/2010 4/16/2011
Leak Detect - Piping Sump Sensor 4/16/2010 4/16/2011
Leak Detect - Tank Automatic Tank Gauging OPW EECO 1500
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 550 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 5/13/1997
OSFM First Notify Date: 4/15/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1971

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/7/2010 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 8/6/2010 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/30/2025 12/30/2026
Leak Detect - Tank Automatic Tank Gauging OPW EECO 1500 12/30/2025 12/30/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 12/30/2025 12/30/2026
Overfill Prev Device Ball Float Vent Valve EBW 308 11/6/2024 11/6/2027
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 11/6/2024 11/6/2027
Leak Detect - Piping Sump Sensor 12/30/2025 12/30/2026
Piping Single Wall Transition Sump 11/6/2024 11/6/2027
Leak Detect - Piping Sump Sensor 12/30/2025 12/30/2026
Spill Contain Device Single Wall Spill Bucket 11/6/2024 11/6/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 12/30/2025
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 12/30/2025



Tank Number 9

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/7/2010 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 8/6/2010 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/30/2025 12/30/2026
Leak Detect - Tank Automatic Tank Gauging OPW EECO 1500 12/30/2025 12/30/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 12/30/2025 12/30/2026
Overfill Prev Device Ball Float Vent Valve EBW 308 11/6/2024 11/6/2027
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 11/6/2024 11/6/2027
Leak Detect - Piping Sump Sensor 12/30/2025 12/30/2026
Piping Single Wall Transition Sump 11/6/2024 11/6/2027
Leak Detect - Piping Sump Sensor 12/30/2025 12/30/2026
Spill Contain Device Double Wall Spill Bucket 11/6/2024 11/6/2027
Tank Fiberglass Double Wall Containment Solutions N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 12/30/2025
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 12/30/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found