Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5022017
Status: Closed
Facility Name: Korner Kwik Stop
Address: 302 West Wood
Camp Point, IL 62320
County: Adams
Property Parcel: 03-0-0467-000-00
Facility Type: Attended Self-Service/Unattended Self-Service
Owner Type: Private
Green Tag Decal: S001283
Green Tag Issue Date: 2/2/2017
Green Tag Expiration Date: 12/31/2019

Owner Details

Owner Name: C & T Enterprises, Inc.
Owner Address: 838 S. 57th Street
Quincy, IL 62035
Owner Status: Current Owner
Purchase Date: 5/11/2009
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/26/2019

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/2/2017 12/31/2019
Unattended Self Service 2/2/2017 12/31/2019

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035787 C & T Enterprises, Inc. Current Owner 5/11/2009
U0035316 D & K Enterprises, Inc. Former Owner 5/8/2009
U0018144 Korner Kwick Stop Inc Former Owner 11/6/1991
U0026602 MJT Co. Former Owner 5/20/1988
U0006193 Griffin Tim & Knopp Kent Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
21-0788 9/20/2021 Removal Log 00986-2021REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
92-1473 Eligible 5/11/2010 7/1/2010 $10,000
20210788 Eligible 11/15/2021 12/8/2021 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/1/1989
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 4/1/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/1/1989
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 1/1/1982 Red Tag Issue Date:
Last Used Date: 4/1/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/20/2021
OSFM First Notify Date: 5/30/1989 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 5/25/1989 Red Tag Issue Date:
Last Used Date: 1/9/2020 Fee Due: $0.00
Product Date: 5/25/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 9/24/2017 9/24/2020
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/4/2018 10/4/2019
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr.
Overfill Prev Device Overfill Drop Tube Valve 8/21/2019 8/21/2022
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/21/2019 8/21/2022
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/20/2021
OSFM First Notify Date: 5/30/1989 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 5/25/1989 Red Tag Issue Date:
Last Used Date: 1/9/2020 Fee Due: $0.00
Product Date: 5/25/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 9/24/2017 9/24/2020
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/4/2018 10/4/2019
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr.
Overfill Prev Device Overfill Drop Tube Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/21/2019 8/21/2022
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/20/2021
OSFM First Notify Date: 3/30/1992 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 9/1/1989 Red Tag Issue Date:
Last Used Date: 9/6/2019 Fee Due: $0.00
Product Date: 9/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 9/24/2017 9/24/2020
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/4/2018 10/4/2019
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr.
Overfill Prev Device Overfill Drop Tube Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/21/2019 8/21/2022
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/20/2021
OSFM First Notify Date: 10/8/1998 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 4/17/1998 Red Tag Issue Date:
Last Used Date: 1/9/2020 Fee Due: $0.00
Product Date: 4/17/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 9/24/2017 9/24/2020
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/4/2018 10/4/2019
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr.
Overfill Prev Device Ball Float Vent Valve 8/21/2019 8/21/2022
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 8 Satelite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found