Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0038991 |
Mitesh Kumar Patel |
Current Owner |
10/31/2017 |
| U0037001 |
Patel, Rasik |
Former Owner |
7/24/2013 |
| U0037001 |
Patel, Rasik |
Former Owner |
7/24/2013 |
| U0037504 |
Auburn Investment Properties, LLC |
Former Owner |
4/1/2013 |
| U0034755 |
Hanuman Grocers, Inc. |
Former Owner |
4/14/2008 |
| U0033202 |
Sweta Grocery, Inc. |
Former Owner |
12/11/2005 |
| U0032771 |
Routemart, Inc. |
Former Owner |
2/2/2005 |
| U0006126 |
Green Oil Company |
Former Owner |
7/12/1987 |
| U0009763 |
Martin & Bayley, Inc. |
Former Owner |
12/31/1967 |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 06-0698 |
6/9/2006 |
Removal Log |
00696-2006REM |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 04-0151 |
Eligible |
3/16/2004
|
3/22/2004
|
$10,000
|
|
Tank Number 1
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
7/2/1987 |
|
Abandoned Material: |
|
| Current Age: |
48 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1978 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
8/14/2026 |
8/14/2027 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
8/14/2026 |
8/14/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 |
8/14/2026 |
8/14/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/12/2025 |
8/12/2028 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
8/12/2025 |
8/12/2028 |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech
|
Precision Test (Piping)
|
Pass
|
8/14/2026
|
Tank Number 2
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
6/9/2006 |
|
OSFM
First Notify Date: |
7/2/1987 |
|
Abandoned Material: |
|
| Current Age: |
28 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1978 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
6/5/2003 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Name\ID 1/2
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
Not applicable
|
Not applicable
|
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable
|
Not applicable
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD