Facility Number: 5020251
Status: Active
Facility Name: Thorntons #370
Address: 2208 Peoria Road
Springfield, IL 62707
County: Sangamon
Property Parcel: 14-15.0-477-023
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000515
Green Tag Issue Date: 5/22/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Thorntons, LLC
Owner Address: 2600 James Thornton Way
Louisville, KY 40245
Owner Status: Current Owner
Purchase Date: 2/11/2019
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/18/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/22/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039521 Thorntons, LLC Current Owner 2/11/2019
U0014995 Thornton's, Inc. - DO NOT USE THIS OWNER ID Former Owner 2/23/2002
U0002187 Burwell Oil Service, Inc. Former Owner 9/10/1987

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
N/A 9/18/2024 Removal Log 00977-2024REM
N/A 9/17/2024 Abandonment Log 00984-2024ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20240771 Eligible 12/3/2024 12/12/2024 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/18/2024
OSFM First Notify Date: 8/11/1987 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/15/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/16/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/28/2024 3/28/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/28/2024 3/28/2025
Overfill Prev Device Overfill Drop Tube Valve 3/30/2023 3/30/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/28/2024 3/28/2027
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/10/2024



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/18/2024
OSFM First Notify Date: 8/11/1987 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/15/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/16/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/28/2024 3/28/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/28/2024 3/28/2025
Overfill Prev Device Overfill Drop Tube Valve 3/30/2023 3/30/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/28/2024 3/28/2027
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/10/2024



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/18/2024
OSFM First Notify Date: 8/11/1987 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/15/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/16/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/28/2024 3/28/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/28/2024 3/28/2025
Overfill Prev Device Overfill Drop Tube Valve 3/30/2023 3/30/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/28/2024 3/28/2027
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 3/28/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/10/2024



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/11/1987 Abandoned Material: Inert material mixed with portland cement
Current Age: 38 Abandoned Date: 9/17/2024
Install Date: 1/15/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/16/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/28/2024 3/28/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/28/2024 3/28/2025
Overfill Prev Device Overfill Drop Tube Valve 3/30/2023 3/30/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/28/2024 3/28/2027
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 3/28/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/10/2024



Tank Number 5

Capacity: 12000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/11/1987 Abandoned Material: Inert material mixed with portland cement
Current Age: 38 Abandoned Date: 9/17/2024
Install Date: 1/15/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/16/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/28/2024 3/28/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/28/2024 3/28/2025
Overfill Prev Device Overfill Drop Tube Valve 5/15/2024 5/15/2027
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Double Wall Spill Bucket 5/15/2024 5/15/2027
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/10/2024



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/11/1987 Abandoned Material: Inert material mixed with portland cement
Current Age: 37 Abandoned Date: 9/17/2024
Install Date: 10/15/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/16/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/28/2024 3/28/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/28/2024 3/28/2025
Overfill Prev Device Overfill Drop Tube Valve 3/30/2023 3/30/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/28/2024 3/28/2027
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 12/12/2023
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/10/2024



Tank Number 7

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/11/1987 Abandoned Material: Inert material mixed with portland cement
Current Age: 37 Abandoned Date: 9/17/2024
Install Date: 10/15/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/16/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Sacrificial Anode Flex Connector 3/30/2023 3/30/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/28/2024 3/28/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/28/2024 3/28/2025
Overfill Prev Device Overfill Drop Tube Valve 3/30/2023 3/30/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 3/28/2024 3/28/2027
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 12/12/2023
Tank Fiberglass Single Wall Precision Test (Tank) Pass 3/28/2024



Tank Number 8

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/2024 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 9/25/2024 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/23/2024

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/12/2025 5/12/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 5/12/2025 5/12/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 5/12/2025 5/12/2026
Overfill Prev Device Overfill Alarm 10/28/2024 10/28/2027
Overfill Prev Device Overfill Drop Tube Valve 10/30/2024 10/30/2027
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping N/A N/A
Piping Single Wall STP/Tanktop Sump 10/28/2024 10/28/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/12/2025 5/12/2026
Spill Contain Device Double Wall Spill Bucket 10/28/2024 10/28/2027
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping Precision Test (Piping) Pass 10/28/2024
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 10/28/2024



Tank Number 9

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/2024 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 9/25/2024 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/23/2024

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/12/2025 5/12/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 5/12/2025 5/12/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 5/12/2025 5/12/2026
Overfill Prev Device Overfill Alarm 10/28/2024 10/28/2027
Overfill Prev Device Overfill Drop Tube Valve 10/30/2024 10/30/2027
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping N/A N/A
Piping Single Wall STP/Tanktop Sump 10/28/2024 10/28/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/12/2025 5/12/2026
Spill Contain Device Double Wall Spill Bucket 10/28/2024 10/28/2027
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping Precision Test (Piping) Pass 10/28/2024
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 10/28/2024



Tank Number 10

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/2024 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 9/25/2024 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/23/2024

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/12/2025 5/12/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 5/12/2025 5/12/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 5/12/2025 5/12/2026
Overfill Prev Device Overfill Alarm 10/28/2024 10/28/2027
Overfill Prev Device Overfill Drop Tube Valve 10/28/2024 10/28/2027
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping N/A N/A
Piping Single Wall STP/Tanktop Sump 10/28/2024 10/28/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/12/2025 5/12/2026
Spill Contain Device Double Wall Spill Bucket 10/28/2024 10/28/2027
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping Precision Test (Piping) Pass 10/28/2024
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 10/28/2024



Tank Number 11

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/2024 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 9/25/2024 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/23/2024

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/12/2025 5/12/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 5/12/2025 5/12/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 5/12/2025 5/12/2026
Overfill Prev Device Overfill Alarm 10/28/2024 10/28/2027
Overfill Prev Device Overfill Drop Tube Valve 10/28/2024 10/28/2027
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping N/A N/A
Piping Single Wall STP/Tanktop Sump 10/28/2024 10/28/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/12/2025 5/12/2026
Spill Contain Device Double Wall Spill Bucket 10/28/2024 10/28/2027
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping Precision Test (Piping) Pass 10/28/2024
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 10/28/2024

Dispenser Information



Name\ID 1/2

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/28/2024 10/28/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/12/2025 5/12/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/28/2024 10/28/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/12/2025 5/12/2026



Name\ID 3/4

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/28/2024 10/28/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/12/2025 5/12/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/28/2024 10/28/2027
Leak Detect - Piping Sump Sensor with positive shutdown 5/12/2025 5/12/2026



Name\ID 7/8

Status: InActive
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
5020251 Thorntons #370 Springfield 08/15/2024 Letter Form