Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5019375
Status: Active
Facility Name: Auburn
Address: 407 East Jackson Auburn, IL 62615
County: Sangamon
Property Parcel:
Facility Type: Attended Self-Service/Unattended Self-Service
Owner Type: Private
Green Tag Decal: Z000499
Green Tag Issue Date: 4/4/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Prairieland FS, Inc.
Owner Address: 1132 Veterans Drive Jacksonville, IL 62650
Owner Status: Current Owner
Purchase Date: 12/1/2013
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/1/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/4/2024 12/31/2026
Unattended Self Service 4/4/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0013645 Prairieland FS, Inc. Current Owner 12/1/2013
U0004992 Lincoln Land FS, Inc. Former Owner 8/1/2001

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 3/26/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/27/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/12/2025 8/12/2026
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC 8/12/2025 8/12/2026
Overfill Prev Device Overfill Drop Tube Valve 5/17/2023 5/17/2026
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 5/17/2023 5/17/2026
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 11/17/2020 11/17/2021
Leak Detect - Piping Sump Sensor 8/12/2025 8/12/2026
Spill Contain Device Single Wall Spill Bucket 5/17/2023 5/17/2026
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 8/12/2025



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 3/26/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/27/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 8/12/2025 8/12/2028
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/12/2025 8/12/2026
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC 8/12/2025 8/12/2026
Overfill Prev Device Overfill Drop Tube Valve 5/17/2023 5/17/2026
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/17/2023 5/17/2026
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 8/12/2025



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 3/26/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/27/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 8/12/2025 8/12/2028
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/12/2025 8/12/2026
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC 8/12/2025 8/12/2026
Overfill Prev Device Overfill Drop Tube Valve 5/17/2023 5/17/2026
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/17/2023 5/17/2026
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 8/12/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/17/2023 5/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/12/2025 8/12/2026



Name\ID 3/4 Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 4 Satelite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/17/2023 5/17/2026
Leak Detect - Piping Sump Sensor 8/12/2025 8/12/2026

MFD Motorfuel Dispensing Forms

No Forms Found