Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5016382
Status: Active
Facility Name: Grand Mart LLC
Address: 102 South 3rd Street Girard, IL 62640
County: Macoupin
Property Parcel: 07-000-723-00
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA001480
Green Tag Issue Date: 5/14/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: FRE TWO LLC
Owner Address: 300 N. Martingale Rd., Suite 750 Schaumburg, IL 60173
Owner Status: Current Owner
Purchase Date: 12/3/2025
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 4/14/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041789 FRE TWO LLC Current Owner 12/3/2025
U0000793 Arnold Owens, Inc. Former Owner 12/11/2000
U0014900 Telzrow Oil Co. Former Owner 12/31/1967
U0023261 Freedom Oil Company Former Owner
U0002261 Wareco Service, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
15-1135 Eligible 12/3/2015 1/8/2016 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/1/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 4/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/1/1986

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/28/2025 10/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 10/28/2025 10/28/2026
Overfill Prev Device Overfill Drop Tube Valve 10/29/2024 10/29/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Flex Connector Steel Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 10/29/2024 10/29/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2024 10/29/2027
Spill Contain Device Single Wall Spill Bucket 10/29/2024 10/29/2027
Tank Fiberglass Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/28/2025



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/1/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 4/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/1/1986

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/28/2025 10/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 10/28/2025 10/28/2026
Overfill Prev Device Overfill Drop Tube Valve 10/29/2024 10/29/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Flex Connector Steel Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 10/29/2024 10/29/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2024 10/29/2027
Spill Contain Device Single Wall Spill Bucket 10/29/2024 10/29/2027
Tank Fiberglass Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/28/2025



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/1/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 4/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/1/1986

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/28/2025 10/28/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 10/28/2025 10/28/2026
Overfill Prev Device Overfill Drop Tube Valve 10/29/2024 10/29/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Flex Connector Steel Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 10/29/2024 10/29/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/29/2024 10/29/2027
Spill Contain Device Single Wall Spill Bucket 10/29/2024 10/29/2027
Tank Fiberglass Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 10/28/2025

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/29/2024 10/29/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/28/2025 10/28/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/29/2024 10/29/2027
Leak Detect - Piping Sump Sensor with positive shutdown 10/28/2025 10/28/2026

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.