Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5012222
Status: Active
Facility Name: Prairieland FS
Address: 6299 Lapraire Rd.
Huntsville, IL 62344
County: Schuyler
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: ZZ00021
Green Tag Issue Date: 11/13/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Prairieland FS, Inc.
Owner Address: 1132 Veterans Drive
Jacksonville, IL 62650
Owner Status: Current Owner
Purchase Date: 12/1/2013
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 2/27/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 11/13/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0013645 Prairieland FS, Inc. Current Owner 12/1/2013

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/15/1994
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 1/1/1983 Red Tag Issue Date:
Last Used Date: 2/15/1994 Fee Due: $0.00
Product Date: 1/1/1983

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/15/1994
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 1/1/1983 Red Tag Issue Date:
Last Used Date: 2/15/1994 Fee Due: $0.00
Product Date: 1/1/1983

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/15/1994
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 1/1/1983 Red Tag Issue Date:
Last Used Date: 2/15/1994 Fee Due: $0.00
Product Date: 1/1/1983

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/16/1994 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 2/15/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/15/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 4/2/2024 4/2/2027
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 4/2/2024 4/2/2027
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 4/8/2025 4/8/2026
Overfill Prev Device Overfill Drop Tube Valve 4/8/2025 4/8/2028
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/8/2025 4/8/2028
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 1000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/16/1994 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 2/15/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/15/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 4/2/2024 4/2/2027
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 4/2/2024 4/2/2027
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 4/8/2025 4/8/2026
Overfill Prev Device Overfill Drop Tube Valve 4/8/2025 4/8/2028
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/8/2025 4/8/2028
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/16/1994 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 2/15/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/15/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 4/2/2024 4/2/2027
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 4/2/2024 4/2/2027
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 4/8/2025 4/8/2026
Overfill Prev Device Overfill Drop Tube Valve 4/8/2025 4/8/2028
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/8/2025 4/8/2028
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found