Facility Details
Facility Number:
5009491
Status:
Active
Facility Name:
Monroe Shell
Address:
2000 W. Monroe
Springfield, IL 62707
County:
Sangamon
Property Parcel:
14-32.0-155-025
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
Y000796
Green Tag Issue Date:
6/7/2023
Green Tag Expiration Date:
12/31/2025
Owner Details
Owner Name:
Brian Lehmann
Owner Address:
2000 W Monroe
Springfield, IL 62704
Owner Status:
Current Owner
Purchase Date:
1/3/2000
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
1/17/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Full Service
8/8/2017
12/31/2019
Self Service
8/8/2017
12/31/2019
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0029225
Lehmann, Brian
Current Owner
1/3/2000
U0013854
Shell Oil Company
Former Owner
12/31/1967
U0023413
Wilkerson Thimothy
Former Owner / Operator
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
18-0604
7/26/2018
Removal Log
00925-2018REM
910764
3/23/1992
Removal Log
920764
3/23/1992
Removal Log
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
92-0764
Eligible
5/27/1994
6/30/1994
$15,000
20180604
Eligible
9/21/2018
10/15/2018
$5,000
Letter
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/23/1992
OSFM
First Notify Date:
3/10/1986
Abandoned Material:
Current Age:
12
Abandoned Date:
Install Date:
3/10/1980
Red Tag Issue Date:
Last Used Date:
4/22/1992
Fee Due:
$0.00
Product Date:
3/10/1980
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/23/1992
OSFM
First Notify Date:
3/10/1986
Abandoned Material:
Current Age:
12
Abandoned Date:
Install Date:
3/10/1980
Red Tag Issue Date:
Last Used Date:
4/22/1992
Fee Due:
$0.00
Product Date:
3/10/1980
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/23/1992
OSFM
First Notify Date:
3/10/1986
Abandoned Material:
Current Age:
12
Abandoned Date:
Install Date:
3/10/1980
Red Tag Issue Date:
Last Used Date:
4/22/1992
Fee Due:
$0.00
Product Date:
3/10/1980
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
550
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
11/26/1986
OSFM
First Notify Date:
3/10/1986
Abandoned Material:
Current Age:
20
Abandoned Date:
Install Date:
3/10/1966
Red Tag Issue Date:
Last Used Date:
11/26/1986
Fee Due:
Product Date:
3/10/1966
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
1000
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
4/4/1994
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
1/1/1989
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
1/1/1989
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Gravity Feed
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging OPW EECO 2000
5/1/2024
5/1/2025
Overfill Prev Device
Less than 25 gallon fills
N/A
N/A
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
2/17/2023
2/17/2026
Tank
Fiberglass Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/26/2018
OSFM
First Notify Date:
7/22/1994
Abandoned Material:
Current Age:
24
Abandoned Date:
Install Date:
1/1/1994
Red Tag Issue Date:
Last Used Date:
4/10/2018
Fee Due:
$0.00
Product Date:
1/1/1994
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
4/4/2017
4/4/2018
Leak Detect - Piping
Sump Sensor
4/4/2017
4/4/2018
Leak Detect - Tank
Automatic Tank Gauging OPW EECO 2000
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Double Wall
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/26/2018
OSFM
First Notify Date:
7/22/1994
Abandoned Material:
Current Age:
24
Abandoned Date:
Install Date:
1/1/1994
Red Tag Issue Date:
Last Used Date:
4/10/2018
Fee Due:
$0.00
Product Date:
1/1/1994
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
4/4/2017
4/4/2018
Leak Detect - Piping
Sump Sensor
4/4/2017
4/4/2018
Leak Detect - Tank
Automatic Tank Gauging OPW EECO 2000
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Double Wall
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/26/2018
OSFM
First Notify Date:
7/22/1994
Abandoned Material:
Current Age:
24
Abandoned Date:
Install Date:
1/1/1994
Red Tag Issue Date:
Last Used Date:
4/10/2018
Fee Due:
$0.00
Product Date:
1/1/1994
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
4/4/2017
4/4/2018
Leak Detect - Piping
Sump Sensor
4/4/2017
4/4/2018
Leak Detect - Tank
Automatic Tank Gauging OPW EECO 2000
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Double Wall
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Fiberglass Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found