Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5008904
Status: Active
Facility Name: Bunker Hill Country Mart
Address: 302 N. Washington Street
Bunker Hill, IL 62014
County: Macoupin
Property Parcel: 15-000-937-00
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000795
Green Tag Issue Date: 5/31/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Harikrishna US Corporation
Owner Address: 302 N. Washington Street
Bunker Hill, IL 62014
Owner Status: Current Owner
Purchase Date: 5/1/2014
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 7/7/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/31/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037697 Harikrishna US Corporation Current Owner 5/1/2014
U0036467 Aving-Rice, LLC Former Owner 2/23/2012
U0033401 SNC JJ Bunker Hill, LLC Former Owner 4/10/2006
U0017339 Niebrugge Oil Company Former Owner 1/8/2002
U0024240 Wolff Oil, Inc. Former Owner 4/15/1998
U0010575 Moore's Oil & Fertilizer, Inc. Former Owner 12/31/1967
U0037889 Patel, Sanjay Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
01659-2024UPG Upgrade Cancelled by Contractor 12/27/2024 12/29/2024 7/1/2025 Documents

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
05-1423 11/29/2007 Abandonment Log 01751-2007ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
05-1423 Eligible 2/25/2010 4/7/2010 $10,000
05-1423 Eligible 9/28/2012 11/20/2012 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 49 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 10/22/2024 10/22/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/22/2024 10/22/2025
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 10/22/2024 10/22/2025
Overfill Prev Device Overfill Drop Tube Valve 10/22/2024 10/22/2027
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/22/2024 10/22/2027
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 49 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 10/22/2024 10/22/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/22/2024 10/22/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/22/2024 10/22/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 10/22/2024 10/22/2025
Overfill Prev Device Overfill Drop Tube Valve 10/22/2024 10/22/2027
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/22/2024 10/22/2027
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 10/22/2024



Tank Number 3

Capacity: 2000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/1/1986 Abandoned Material:
Current Age: 47 Abandoned Date:
Install Date: 1/1/1978 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1978

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 10/22/2024 10/22/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/22/2024 10/22/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/22/2024 10/22/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 10/22/2024 10/22/2025
Overfill Prev Device Overfill Drop Tube Valve 10/22/2024 10/22/2027
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/22/2024 10/22/2027
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 10/22/2024



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/29/1988 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 10/22/2024 10/22/2025
Corrosion Prot - Tank Impressed Current Cathodic Protection 10/22/2024 10/22/2025
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/22/2024 10/22/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 10/22/2024 10/22/2025
Overfill Prev Device Overfill Drop Tube Valve 10/22/2024 10/22/2027
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/18/2022 10/22/2024
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 10/22/2024



Tank Number 5

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/29/1988 Abandoned Material: Inert material mixed with portland cement
Current Age: 37 Abandoned Date: 11/29/2007
Install Date: 1/1/1988 Red Tag Issue Date:
Last Used Date: 6/23/2005 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found