Facility Details
Facility Number:
5007153
Status:
Closed
Facility Name:
T-Mart #323
Address:
811 Spresser
Yan & Associates/Operator
Taylorville, IL 62568
County:
Christian
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
H001304
Green Tag Issue Date:
12/13/2006
Green Tag Expiration Date:
12/31/2009
Owner Details
Owner Name:
Yan & Associates, Inc.
Owner Address:
4309 Hatch Lane
Lisle, IL 60532
Owner Status:
Current Owner / Operator
Purchase Date:
12/8/2005
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
5/12/2004
12/15/2005
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0032010
Yan & Associates, Inc.
Current Owner / Operator
12/8/2005
U0031532
Baker Energy, Inc.
Former Owner
8/27/2003
U0029789
Clark Retail Enterprises, Inc.
Former Owner
3/7/2001
U0002262
Wareco Service, Inc.
Former Owner
8/1/1995
U0003148
Coastal Mart Inc
Former Owner
10/25/1990
U0004020
Derby Refining Comapny
Former Owner
12/31/1967
U0032358
SKS Ventures, LLC
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
09-0449
6/25/2009
Removal Log
00666-2009REM
09-0449
6/26/2009
Removal Log
00666-2009REM
090449
6/25/2009
Removal Log
00666-2009REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
95-1412
Eligible
2/28/1996
3/21/1996
$10,000
95-1412
Eligible
3/25/2005
4/13/2005
$10,000
99-2014
Eligible
3/25/2005
4/13/2005
$10,000
00-1504
Eligible
3/25/2005
4/13/2005
$10,000
99-2014
Eligible
4/20/2005
5/25/2005
$10,000
09-0449
Eligible
5/22/2009
6/12/2009
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/25/2009
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
38
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
2/20/2007
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
Leak Detect - Tank
Monthly Inv Ctrl and Prec Tight Testing
Overfill Prev Device
Ball Float Vent Valve OPW 53
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Single Wall Piping Ameron
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/25/2009
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
38
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
2/20/2007
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
Leak Detect - Tank
Monthly Inv Ctrl and Prec Tight Testing
Overfill Prev Device
Ball Float Vent Valve OPW 53
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Single Wall Piping Ameron
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
6/26/2009
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
38
Abandoned Date:
Install Date:
1/1/1971
Red Tag Issue Date:
Last Used Date:
2/20/2007
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
Leak Detect - Tank
Monthly Inv Ctrl and Prec Tight Testing
Overfill Prev Device
Ball Float Vent Valve OPW 53
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Single Wall Piping Ameron
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found