Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5001144
Status: Active
Facility Name: Seeret Ayzel, Inc.
Address: 5 W. Cherry Street Winchester, IL 62694
County: Scott
Property Parcel: 0629203013
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01461
Green Tag Issue Date: 4/11/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Seeret Ayzel, Inc.
Owner Address: 5 W. Cherry Street Winchester, IL 62694
Owner Status: Current Owner
Purchase Date: 2/19/2019
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 6/15/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/11/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039454 Seeret Ayzel, Inc. Current Owner 2/19/2019
U0038849 Sukhwinder, Kaur Former Owner 8/13/2013
U0037010 Winchester Food Mart, Inc. Former Owner 8/13/2013
U0004981 Fanning Oil Company, Inc. Former Owner 1/1/1964

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020253008 (Pending)    Issue Date: 11/12/2025    Expiration Date: 1/11/2026    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
4, 5, 6 Annual leak detection certification not completed (Required annually).
Facility Missing copies of Annual Walkthrough Inspection Report.
4, 5, 6 Overfill prevention equipment inspection(s) not completed (Required every 3 years).
4, 5, 6 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection).
4, 5, 6 Triennial spill prevention equipment testing not completed.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
93-1027 4/23/1993 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
93-1027 Eligible 6/16/1994 7/8/1994 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/23/1993
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/1/1964 Red Tag Issue Date:
Last Used Date: 4/20/1993 Fee Due: $0.00
Product Date: 1/1/1964

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/23/1993
OSFM First Notify Date: 6/3/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/1/1964 Red Tag Issue Date:
Last Used Date: 4/20/1993 Fee Due: $0.00
Product Date: 1/1/1964

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/23/1993
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/1/1964 Red Tag Issue Date:
Last Used Date: 4/20/1993 Fee Due: $0.00
Product Date: 1/1/1964

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/28/1998 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/1/1993 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/18/2025 11/18/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/18/2025 11/18/2026
Overfill Prev Device Overfill Drop Tube Valve 11/18/2025 11/18/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/18/2025 11/18/2028
Tank Fiberglass Single Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 11/18/2025



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/28/1998 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/1/1993 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/18/2025 11/18/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/18/2025 11/18/2026
Overfill Prev Device Overfill Drop Tube Valve 11/18/2025 11/18/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/18/2025 11/18/2028
Tank Fiberglass Single Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 11/18/2025



Tank Number 6

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/28/1998 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/1/1993 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/18/2025 11/18/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 11/18/2025 11/18/2026
Overfill Prev Device Overfill Drop Tube Valve 11/18/2025 11/18/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/18/2025 11/18/2028
Tank Fiberglass Single Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 11/18/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found