Facility Details
Facility Number:
5001140
Status:
Active
Facility Name:
Waverly Gas Mart, Inc.
Address:
405 W. Elm Street
Waverly, IL 62692
County:
Morgan
Property Parcel:
19-11-102-025
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
Y000734
Green Tag Issue Date:
4/27/2023
Green Tag Expiration Date:
12/31/2025
Owner Details
Owner Name:
Ada Singh, LLC
Owner Address:
1833 Avnel Lane
Chatham, IL 62629
Owner Status:
Current Owner
Purchase Date:
1/3/2020
Type of Financial Responsibility:
Certificate of Deposit
Financial Responsibility Reporting Due Date:
11/3/2024
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
4/27/2023
12/31/2025
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0039745
Ada Singh, LLC
Current Owner
1/3/2020
U0039246
Fanning Fuel Co.
Former Owner
4/10/2018
U0037571
Meera Shakti, Inc. / Meera, LLC
Former Owner
U0037571
Meera Shakti, Inc. / Meera, LLC
Former Owner
U0004981
Fanning Oil Company, Inc.
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
90-1212
5/13/2013
Abandonment Log
00325-2013ABN
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
90-1212
Eligible
6/11/1998
7/1/1998
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Abandoned in place
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/6/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
34
Abandoned Date:
5/13/2013
Install Date:
Red Tag Issue Date:
Last Used Date:
3/26/2013
Fee Due:
$0.00
Product Date:
5/10/1990
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
1/7/2013
1/7/2014
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Impressed Current Cathodic Protection
1/7/2013
1/7/2014
Corrosion Prot - Tank
Lining Materials Internal
3/26/2013
3/26/2018
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
7/3/2012
7/3/2013
Leak Detect - Tank
Automatic Tank Gauging Gilbarco Tank Monitor 2
Overfill Prev Device
Ball Float Vent Valve
Piping
Flex Connector Steel
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
6000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Abandoned in place
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/6/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
34
Abandoned Date:
5/13/2013
Install Date:
Red Tag Issue Date:
Last Used Date:
3/26/2013
Fee Due:
$0.00
Product Date:
5/10/1990
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
1/7/2013
1/7/2014
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Impressed Current Cathodic Protection
1/7/2013
1/7/2014
Corrosion Prot - Tank
Lining Materials Internal
3/26/2013
3/26/2018
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
7/3/2012
7/3/2013
Leak Detect - Tank
Automatic Tank Gauging Gilbarco Tank Monitor 2
Overfill Prev Device
Ball Float Vent Valve
Piping
Flex Connector Steel
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
2000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/1/1990
OSFM
First Notify Date:
3/6/1986
Abandoned Material:
Current Age:
18
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
1000
Petroleum Use:
Product:
Kerosene
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/1/1990
OSFM
First Notify Date:
3/6/1986
Abandoned Material:
Current Age:
14
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
6000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
12/15/1993
Abandoned Material:
Current Age:
34
Abandoned Date:
Install Date:
5/10/1990
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
5/10/1990
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
6/29/2022
6/29/2025
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
4/22/2024
4/22/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
4/22/2024
4/22/2025
Overfill Prev Device
Ball Float Vent Valve
6/29/2022
6/29/2025
Piping
Flex Connector Steel
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
6/29/2022
6/29/2025
Tank
Fiberglass Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping
Precision Test (Piping)
Pass
4/22/2024
Tank Number 6
Capacity:
6000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
12/15/1993
Abandoned Material:
Current Age:
34
Abandoned Date:
Install Date:
5/10/1990
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
5/10/1990
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Flex Connector
6/29/2022
6/29/2025
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
4/22/2024
4/22/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
4/22/2024
4/22/2025
Overfill Prev Device
Ball Float Vent Valve
6/29/2022
6/29/2025
Piping
Flex Connector Steel
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
6/29/2022
6/29/2025
Tank
Fiberglass Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping
Precision Test (Piping)
Pass
4/22/2024
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found