Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4047440
Status: Active
Facility Name: Love's Travel Stops #867
Address: 2007 N. Main Street
Normal, IL 61761
County: McLean
Property Parcel: 14-16-151-001
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z002061
Green Tag Issue Date: 11/19/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Love's Travel Stops & Country Stores, Inc.
Owner Address: 10601 N. Penn
P.O. Box 26210
Oklahoma City, OK 73120
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/29/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 11/19/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030965 Love's Travel Stops & Country Stores, Inc. Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: E15 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/25/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/14/2024 8/14/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/14/2024 8/14/2025
Overfill Prev Device Overfill Alarm 8/28/2023 8/28/2026
Overfill Prev Device Overfill Drop Tube Valve 8/28/2023 8/28/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/18/2022 11/18/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025
Piping Single Wall Transition Sump 11/18/2022 11/18/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025
Spill Contain Device Single Wall Spill Bucket 8/28/2023 8/28/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 8/28/2023
Tank Fiberglass Double Wall Precision Test (Tank) Pass 11/18/2022



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: E15 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/25/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/14/2024 8/14/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/14/2024 8/14/2025
Overfill Prev Device Overfill Alarm 8/28/2023 8/28/2026
Overfill Prev Device Overfill Drop Tube Valve 8/28/2023 8/28/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/18/2022 11/18/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025
Piping Single Wall Transition Sump 11/18/2022 11/18/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025
Spill Contain Device Single Wall Spill Bucket 8/28/2023 8/28/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 8/28/2023



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/25/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/14/2024 8/14/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/14/2024 8/14/2025
Overfill Prev Device Overfill Alarm 8/28/2023 8/28/2026
Overfill Prev Device Overfill Drop Tube Valve 8/28/2023 8/28/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/18/2022 11/18/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025
Piping Single Wall Transition Sump 11/18/2022 11/18/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025
Spill Contain Device Single Wall Spill Bucket 8/28/2023 8/28/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 8/28/2023
Tank Fiberglass Double Wall Precision Test (Tank) Pass 11/18/2022



Tank Number 4

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/23/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/14/2024 8/14/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/14/2024 8/14/2025
Overfill Prev Device Overfill Alarm 8/28/2023 8/28/2026
Overfill Prev Device Overfill Drop Tube Valve 8/28/2023 8/28/2026
Piping Blending Sump 11/18/2022 11/18/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/18/2022 11/18/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025
Piping Single Wall Transition Sump 11/18/2022 11/18/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025
Spill Contain Device Single Wall Spill Bucket 8/28/2023 8/28/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Blending Sump Precision Test (Piping) Pass 8/28/2023
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 8/28/2023
Tank Fiberglass Double Wall Precision Test (Tank) Pass 11/18/2022



Tank Number 5

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/23/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/14/2024 8/14/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/14/2024 8/14/2025
Overfill Prev Device Overfill Alarm 8/28/2023 8/28/2026
Overfill Prev Device Overfill Drop Tube Valve 8/28/2023 8/28/2026
Piping Blending Sump 11/18/2022 11/18/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/18/2022 11/18/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025
Piping Single Wall Transition Sump 11/18/2022 11/18/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025
Spill Contain Device Single Wall Spill Bucket 8/28/2023 8/28/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Blending Sump Precision Test (Piping) Pass 8/28/2023
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 8/28/2023
Tank Fiberglass Double Wall Precision Test (Tank) Pass 11/18/2022



Tank Number 6

Capacity: 20000 Petroleum Use:
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/30/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/14/2024 8/14/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/14/2024 8/14/2025
Overfill Prev Device Overfill Alarm 8/28/2023 8/28/2026
Overfill Prev Device Overfill Drop Tube Valve 8/28/2023 8/28/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 11/18/2022 11/18/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025
Spill Contain Device Single Wall Spill Bucket 8/28/2023 8/28/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test (Piping) Pass 8/14/2024
Tank Fiberglass Double Wall Precision Test (Tank) Pass 11/18/2022



Tank Number 7

Capacity: 3000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/18/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/14/2024 8/14/2025
Overfill Prev Device Overfill Alarm 8/29/2023 8/29/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket Horizontal Cabinet 8/29/2023 8/29/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 11/18/2022



Tank Number 8

Capacity: 8000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/18/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/14/2024 8/14/2025
Overfill Prev Device Overfill Alarm 8/29/2023 8/29/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket Horizontal Cabinet 8/29/2023 8/29/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 11/18/2022



Tank Number 9

Capacity: 3000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/18/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/14/2024 8/14/2025
Overfill Prev Device Overfill Alarm 8/29/2023 8/29/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket Horizontal Cabinet 8/29/2023 8/29/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 11/18/2022



Tank Number 10

Capacity: 3000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/18/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/14/2024 8/14/2025
Overfill Prev Device Overfill Alarm 8/29/2023 8/29/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket Horizontal Cabinet 8/29/2023 8/29/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 11/18/2022



Tank Number 11

Capacity: 3000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/18/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/14/2024 8/14/2025
Overfill Prev Device Overfill Alarm 8/29/2023 8/29/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket Horizontal Cabinet 8/29/2023 8/29/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 11/18/2022



Tank Number 12

Capacity: 8000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/18/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/14/2024 8/14/2025
Overfill Prev Device Overfill Alarm 8/29/2023 8/29/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket Horizontal Cabinet 8/29/2023 8/29/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 11/18/2022



Tank Number 13

Capacity: 7000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 8/18/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Gravity Feed N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/14/2024 8/14/2025
Overfill Prev Device Overfill Alarm 8/29/2023 8/29/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/29/2023 8/29/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 11/18/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/16/2022 8/16/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/16/2022 8/16/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/16/2022 8/16/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/16/2022 8/16/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 17M/18S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/30/2022 9/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 17S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/30/2022 9/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 18M19S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/30/2022 9/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 19M/20S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/30/2022 9/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 20M/212S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/30/2022 9/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 21M/22S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/30/2022 9/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 22M/23S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/30/2022 9/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 23M/24S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/30/2022 9/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 24M/25S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/30/2022 9/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 25M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/30/2022 9/30/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/16/2022 8/16/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/14/2024 8/14/2027
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/16/2022 8/16/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/16/2022 8/16/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/14/2024 8/14/2025

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
4047440 Love's Travel Stops #867 Normal 10/24/2022 Letter Form