Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4046677
Status: Active
Facility Name: Love's Travel Stop #746
Address: 3925 County Fair Drive
Decatur, IL 62526
County: Macon
Property Parcel: 07-07-29-451-001
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002341
Green Tag Issue Date: 10/5/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Love's Travel Stops & Country Stores, Inc.
Owner Address: 10601 N. Penn
P.O. Box 26210
Oklahoma City, OK 73120
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/29/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 10/5/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030965 Love's Travel Stops & Country Stores, Inc. Current Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00267-2025UPG Upgrade Approved / Issued 3/4/2025 3/6/2025 9/8/2025 Documents

Notice of Violations (Current)

NOV Number: E0020250832 (Pending)    Issue Date: 3/31/2025    Expiration Date: 5/30/2025    View NOV Form

Tanks Violation
6 Annual leak detection certification not completed (Required annually). - Annual leak detection expired on 1/11/2025 and needs tested. Tank #6 (B-99).
5 Tank interstitial sensors in alarm or failed test, must repair or replace. - Sensor failed on 12/05/2024 and needs repaired and tested. Tank #5 (Diesel)

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: E15 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 9/7/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/13/2019

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/5/2024 12/5/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 12/5/2024 12/5/2025
Overfill Prev Device Overfill Alarm 2/2/2023 2/2/2026
Overfill Prev Device Overfill Drop Tube Valve 2/2/2023 2/2/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025
Spill Contain Device Single Wall Spill Bucket 1/16/2025 1/16/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/12/2020
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 3/12/2020



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 4/10/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 9/7/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Overfill Alarm
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Sump Sensor
Spill Contain Device Field Constructed
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 9/7/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/13/2019

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/5/2024 12/5/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 12/5/2024 12/5/2025
Overfill Prev Device Overfill Alarm 2/2/2023 2/2/2026
Overfill Prev Device Overfill Drop Tube Valve 2/2/2023 2/2/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025
Spill Contain Device Single Wall Spill Bucket 1/16/2025 1/16/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/12/2020
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 3/12/2020



Tank Number 4

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 9/7/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/13/2019

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/5/2024 12/5/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 12/5/2024 12/5/2025
Overfill Prev Device Overfill Alarm 2/2/2023 2/2/2026
Overfill Prev Device Overfill Drop Tube Valve 2/2/2023 2/2/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025
Piping Single Wall Transition Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025
Spill Contain Device Single Wall Spill Bucket 1/16/2025 1/16/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/11/2025
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 3/12/2020



Tank Number 5

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 9/7/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/13/2019

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/5/2024 12/5/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 1/11/2024 12/5/2024
Overfill Prev Device Overfill Alarm 2/2/2023 2/2/2026
Overfill Prev Device Overfill Drop Tube Valve 2/2/2023 2/2/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025
Piping Single Wall Transition Sump 1/16/2025 1/16/2028
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 2/2/2023 2/2/2024
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025
Spill Contain Device Single Wall Spill Bucket 1/16/2025 1/16/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/12/2020
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 3/12/2020



Tank Number 6

Capacity: 20000 Petroleum Use: None
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/2019 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 9/7/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/13/2019

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/11/2024 1/11/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 12/5/2024 12/5/2025
Overfill Prev Device Overfill Alarm 2/2/2023 2/2/2026
Overfill Prev Device Overfill Drop Tube Valve 2/2/2023 2/2/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025
Piping Single Wall Transition Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025
Spill Contain Device Single Wall Spill Bucket 1/16/2025 1/16/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 12/6/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 3/12/2020

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025



Name\ID 17

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025



Name\ID 18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025



Name\ID 19

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025



Name\ID 20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025



Name\ID 21

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025



Name\ID 22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025



Name\ID 23

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025



Name\ID 23S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/16/2025 1/16/2028
Leak Detect - Piping Sump Sensor with positive shutdown 12/5/2024 12/5/2025

MFD Motorfuel Dispensing Forms

No Forms Found