Facility Details
Facility Number:
4043614
Status:
Closed
Facility Name:
Schnucks Champaign Fuel Center
Address:
101 North Mattis Avenue
Champaign, IL 61821
County:
Champaign
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
U005062
Green Tag Issue Date:
4/24/2019
Green Tag Expiration Date:
12/31/2021
Owner Details
Owner Name:
Schnuck Markets, Inc.
Owner Address:
11420 Lakeland Road
Saint Louis, MO 63416
Owner Status:
Current Owner
Purchase Date:
1/1/2007
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
9/23/2020
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Unattended Self Service
4/24/2019
12/31/2021
Self Service
9/8/2015
12/31/2017
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0034061
Schnuck Markets, Inc.
Current Owner
1/1/2007
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
2020-0542
7/21/2020
Removal Log
00932-2020REM
2020-0542
7/20/2020
Removal Log
00932-2020REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
20200542
Eligible
10/8/2020
10/13/2020
$5,000
Letter
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
20000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/21/2020
OSFM
First Notify Date:
10/2/2007
Abandoned Material:
Current Age:
12
Abandoned Date:
Install Date:
5/18/2007
Red Tag Issue Date:
Last Used Date:
9/30/2019
Fee Due:
$0.00
Product Date:
9/24/2007
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
10/22/2019
10/22/2020
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
9/26/2018
9/26/2019
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
9/26/2018
9/26/2019
Overfill Prev Device
Overfill Drop Tube Valve
3/27/2019
3/27/2022
Piping
Fiberglass Double Wall Ameron
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
3/27/2019
3/27/2022
Leak Detect - Piping
Sump Sensor
9/26/2018
9/26/2019
Spill Contain Device
Single Wall Spill Bucket
10/29/2018
10/29/2021
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
6000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/20/2020
OSFM
First Notify Date:
10/2/2007
Abandoned Material:
Current Age:
12
Abandoned Date:
Install Date:
5/18/2007
Red Tag Issue Date:
Last Used Date:
9/30/2019
Fee Due:
$0.00
Product Date:
9/24/2007
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
10/22/2019
10/22/2020
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
9/26/2018
9/26/2019
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
9/26/2018
9/26/2019
Overfill Prev Device
Overfill Drop Tube Valve
10/29/2018
10/29/2021
Piping
Fiberglass Double Wall Ameron
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
3/27/2019
3/27/2022
Leak Detect - Piping
Sump Sensor
9/26/2018
9/26/2019
Spill Contain Device
Single Wall Spill Bucket
10/29/2018
10/29/2021
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
6000
Petroleum Use:
Product:
E85
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/20/2020
OSFM
First Notify Date:
10/2/2007
Abandoned Material:
Current Age:
12
Abandoned Date:
Install Date:
5/18/2007
Red Tag Issue Date:
Last Used Date:
9/30/2019
Fee Due:
$0.00
Product Date:
9/24/2007
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
10/22/2019
10/22/2020
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
9/26/2018
9/26/2019
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
9/26/2018
9/26/2019
Overfill Prev Device
Overfill Drop Tube Valve
4/10/2019
4/10/2022
Piping
Fiberglass Double Wall Ameron
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
3/27/2019
3/27/2022
Leak Detect - Piping
Sump Sensor
9/26/2018
9/26/2019
Spill Contain Device
Double Wall Spill Bucket
3/27/2019
3/27/2022
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/27/2019
3/27/2022
Leak Detect - Piping
Sump Sensor
9/26/2018
9/26/2019
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/27/2019
3/27/2022
Leak Detect - Piping
Sump Sensor
9/26/2018
9/26/2019
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/27/2019
3/27/2022
Leak Detect - Piping
Sump Sensor
9/26/2018
9/26/2019
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/27/2019
3/27/2022
Leak Detect - Piping
Sump Sensor
9/26/2018
9/26/2019
Name\ID 9/10
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
3/27/2019
3/27/2022
Leak Detect - Piping
Sump Sensor
9/26/2018
9/26/2019
MFD
Motorfuel Dispensing Forms
No Forms Found