Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4039494
Status: Active
Facility Name: Casey's General Store 2267
Address: 1930 North Linden Street
Normal, IL 61761
County: McLean
Property Parcel: 14-15-154-001
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002326
Green Tag Issue Date: 8/22/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Casey's Retail Company
Owner Address: 3305 SE Delaware Ave.
P.O. Box 3004
Ankeny, IA 50021
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/27/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/22/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0002560 Casey's Retail Company Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020251120 (Pending)    Issue Date: 4/28/2025    Expiration Date: 6/27/2025    View NOV Form

Tanks Violation
1, 2 Annual electronic line leak detector test not completed. - Expired 4/2/2025.
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - No prior or current year Annual Emergency Stop inspection report available on site.
1, 2 Annual leak detection certification not completed (Required annually). - Expired 4/2/2025.
Facility Facility Operation and Maintenance Plan not completed or available. - No Operation and Maintenance plan available on site.
1, 2 Flex connector sacrificial anode system not tested (required every 3 years) - Test anodes and replace as needed - Expired 4/5/2025.
Facility Missing copies of Annual Walkthrough Inspection Report. - No prior or current year Annual Walkthrough Inspection report available on site.
Facility Missing copies of current testing certificates for operator training - Missing copies of current C certificates.
1, 2 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection). - No prior or current year Shear Valve Inspection report on site.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/21/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 5/17/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/17/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/5/2022 4/5/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/2/2024 4/2/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/2/2024 4/2/2025
Overfill Prev Device Ball Float Vent Valve OPW 53VM 5/23/2023 5/23/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 7/15/2024 7/15/2027
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/21/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 5/17/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/17/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/5/2022 4/5/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/2/2024 4/2/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/2/2024 4/2/2025
Overfill Prev Device Ball Float Vent Valve OPW 53VM 5/23/2023 5/23/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 7/15/2024 7/15/2027
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found