Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4035875
Status: Active
Facility Name: I & I Deli, Inc.
Address: 304 W. Ashmore P.O. Box 317 Ashmore, IL 61812
County: Coles
Property Parcel: 01002923001
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: BB00476
Green Tag Issue Date: 7/29/2026
Green Tag Expire Date: 12/31/2028
MFD Type: Self Service

Owner Details

Owner Name: I & I Deli, Inc.
Owner Address: P.O. Box 317 Ashmore, IL 61912
Owner Status: Current Owner
Purchase Date: 11/1/2001
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/6/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0031640 I & I Deli, Inc. Current Owner 11/1/2001
U0017355 Richey Donald Former Owner 7/1/1991

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/19/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 8/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1991

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/2/2024 10/2/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/2/2025 10/2/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i 10/2/2025 10/2/2026
Overfill Prev Device Overfill Drop Tube Valve 11/17/2023 11/17/2026
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 10/4/2023 10/4/2026
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/2/2025



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/19/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 8/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1991

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/2/2024 10/2/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/2/2025 10/2/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i 10/2/2025 10/2/2026
Overfill Prev Device Overfill Drop Tube Valve 11/17/2023 11/17/2026
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 10/4/2023 10/4/2026
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/2/2025



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/19/1991 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 8/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1991

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/2/2024 10/2/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/2/2025 10/2/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300i 10/2/2025 10/2/2026
Overfill Prev Device Overfill Drop Tube Valve 11/17/2023 11/17/2026
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 10/4/2023 10/4/2026
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 10/2/2025

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found