Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4032269
Status: Active
Facility Name: Carri Scharf Trucking, Inc.
Address: 7 Carri Drive
Bloomington, IL 61705
County: McLean
Property Parcel:
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Z001082
Green Tag Issue Date: 10/15/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Carri Scharf Trucking, Inc.
Owner Address: 7 Carri Drive
Bloomington, IL 61705
Owner Status: Current Owner
Purchase Date: 9/1/1993
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/29/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 10/15/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0021766 Carri Scharf Trucking, Inc. Current Owner 9/1/1993

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/18/1998 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 9/13/1993 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/13/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 7/31/2024 7/31/2025
Overfill Prev Device Overfill Drop Tube Valve 8/2/2022 8/2/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/2/2022 8/2/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/15/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 12/23/2003 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/30/2003

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 7/31/2024 7/31/2025
Overfill Prev Device Overfill Drop Tube Valve 8/2/2022 8/2/2025
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/2/2022 8/2/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID E Pump

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID W Pump

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms