Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4024745
Status: Closed
Facility Name: Bloomington-Normal Transit System
Address: 104 East Oakland Avenue
Bloomington, IL 61701
County: McLean
Property Parcel:
Facility Type: City / Town
Owner Type: Municipal
Green Tag Decal: L007370
Green Tag Issue Date: 3/16/2010
Green Tag Expiration Date: 12/31/2012

Owner Details

Owner Name: Bloomington Normal Public Transit System
Owner Address: 351 Wylie Drive
Normal, IL 61761
Owner Status: Current Owner
Purchase Date: 1/1/1972
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 8/4/2015

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0001665 Bloomington Normal Public Transit System Current Owner 1/1/1972

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
15-0494 5/27/2015 Removal Log 00386-2015REM
18-0124 2/13/2018 Removal Log 00144-2018REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
99-0802 Eligible 5/19/1999 6/2/1999 $15,000
15-0494 Eligible 5/8/2015 6/11/2015 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/27/2015
OSFM First Notify Date: 11/29/1988 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 10/17/1988 Red Tag Issue Date:
Last Used Date: 6/21/2011 Fee Due: $0.00
Product Date: 10/17/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/10/2009 6/10/2010
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001
Overfill Prev Device Overfill Drop Tube Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/2/1999
OSFM First Notify Date: 11/17/1998 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 12/1/1978 Red Tag Issue Date:
Last Used Date: 12/15/1998 Fee Due: $0.00
Product Date: 12/1/1978

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 15000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/17/1988
OSFM First Notify Date: 11/29/1988 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/17/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 560 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 2/13/2018
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms