Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4023966
Status: Active
Facility Name: Watseka CO
Address: 118 South 4th Watseka, IL 60970
County: Iroquois
Property Parcel:
Facility Type: Utility
Owner Type: Private
Green Tag Decal: BB03771
Green Tag Issue Date: 2/5/2026
Green Tag Expire Date: 12/31/2028
MFD Type: N/A

Owner Details

Owner Name: AT&T Corp.
Owner Address: 311 S. Akard Street, Room 12 Dallas, TX 75202
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/11/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034340 AT&T Corp. Current Owner
U0007227 Ameritech d/b/a AT&T Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/6/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 5/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/19/1986

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/19/2026 2/19/2027
Overfill Prev Device Overfill Alarm 2/19/2026 2/19/2029
Overfill Prev Device Overfill Drop Tube Valve 2/19/2026 2/19/2029
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 2/19/2026 2/19/2029
Tank Fiberglass Double Wall Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms