Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4021695
Status: Active
Facility Name: Pari Food, Inc.
Address: 100 N. Grant St. Clinton, IL 61727
County: Dewitt
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA001030
Green Tag Issue Date: 5/20/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: Amanjit Kaur
Owner Address: 100 N. Grant St. Clinton, IL 61727
Owner Status: Current Owner
Purchase Date: 7/16/2016
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 5/20/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038727 Kaur, Amanjit Current Owner 7/16/2016
U0035725 Clinton Food & Gas Former Owner 1/1/2010
U0033212 Labaka, Ramu Former Owner 3/1/2005
U0006126 Green Oil Company Former Owner 3/16/1987
U0009763 Martin & Bayley, Inc. Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
94-0004 Eligible 1/13/1994 1/27/1994 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/2/1987 Abandoned Material: Inert material mixed with portland cement
Current Age: 45 Abandoned Date: 4/16/1997
Install Date: 8/1/1981 Red Tag Issue Date:
Last Used Date: 1/10/1994 Fee Due: $0.00
Product Date: 8/1/1981

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/2/1987 Abandoned Material: Inert material mixed with portland cement
Current Age: 45 Abandoned Date: 4/16/1997
Install Date: 8/1/1981 Red Tag Issue Date:
Last Used Date: 1/10/1994 Fee Due: $0.00
Product Date: 8/1/1981

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/2/1987 Abandoned Material: Inert material mixed with portland cement
Current Age: 45 Abandoned Date: 3/1/2011
Install Date: 8/1/1981 Red Tag Issue Date:
Last Used Date: 6/2/2010 Fee Due: $0.00
Product Date: 8/1/1981

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/19/2010 5/19/2013
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Lining Materials Internal 12/20/2004 12/20/2009
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/28/2008 5/28/2009
Leak Detect - Tank Automatic Tank Gauging Incon TS 750 No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Stainless Steel Single Wall Piping Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/2/1987 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 8/1/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1981

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/24/2026 7/24/2029
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/24/2026 7/24/2029
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/24/2026 7/24/2029
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/24/2026 7/24/2027
Leak Detect - Tank Automatic Tank Gauging Incon TS 750 7/24/2026 7/24/2027
Overfill Prev Device Overfill Drop Tube Valve 4/29/2025 4/29/2028
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Stainless Steel Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 4/29/2025 4/29/2028
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 7/24/2026
Piping Stainless Steel Single Wall Piping Precision Test (Piping) Pass 4/29/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 5/26/2023

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found