Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4020885
Status: Closed
Facility Name: Casey's General Store
Address: 209 W. Washington Street
Le Roy, IL 61752
County: McLean
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: S000006
Green Tag Issue Date: 1/10/2017
Green Tag Expiration Date: 12/31/2019

Owner Details

Owner Name: Casey's Retail Company
Owner Address: 3305 SE Delaware Ave.
P.O. Box 3004
Ankeny, IA 50021
Owner Status: Current Owner
Purchase Date: 9/30/1987
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/27/2018

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/10/2017 12/31/2019

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0002560 Casey's Retail Company Current Owner 9/30/1987

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
98-2502 Eligible 2/17/1999 3/29/1999 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/20/2018
OSFM First Notify Date: 9/25/1987 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 6/1/1987 Red Tag Issue Date:
Last Used Date: 11/26/2017 Fee Due: $0.00
Product Date: 6/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/3/2017 4/3/2018
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/20/2018
OSFM First Notify Date: 9/25/1987 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 6/1/1987 Red Tag Issue Date:
Last Used Date: 11/26/2017 Fee Due: $0.00
Product Date: 6/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/3/2017 4/3/2018
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found