Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4017450
Status: Closed
Facility Name: Armstrong Center
Address: 1400 Piatt Avenue
Mattoon, IL 61938
County: Coles
Property Parcel:
Facility Type: School/College
Owner Type: Other Local
Green Tag Decal: L007457
Green Tag Issue Date: 4/15/2010
Green Tag Expiration Date: 12/31/2012

Owner Details

Owner Name: Mattoon Community School
Owner Address: 1400 Piatt Avenue
Mattoon, IL 61938
Owner Status: Current Owner
Purchase Date: 7/1/1976
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/19/2013

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0009872 Mattoon Community School Current Owner 7/1/1976

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
12-0191 4/10/2012 Removal Log 00251-2012REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
12-0191 Eligible 6/21/2012 6/21/2012 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/10/2012
OSFM First Notify Date: 4/11/1986 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 7/1/1976 Red Tag Issue Date:
Last Used Date: 11/1/2011 Fee Due: $0.00
Product Date: 7/1/1976

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 4/13/2010 4/13/2013
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 4/13/2010 4/13/2013
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1000
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 7500 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Pre 1974 CAS Code:
Regulated Status: Exempt Removed Date:
OSFM First Notify Date: 3/14/1990 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 5/1/1962 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/10/2012
OSFM First Notify Date: 10/15/1990 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/22/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 4/13/2010 4/13/2013
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 4/13/2010 4/13/2013
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1000
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information