Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4015947
Status: Active
Facility Name: Three Corners Grain, LLC
Address: 99 East 100 North Road
Foosland, IL 61845
County: Ford
Property Parcel: 09-11-31-200-005
Facility Type: Farm
Owner Type: Private
Green Tag Decal: Z003621
Green Tag Issue Date: 3/1/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Three Corners Grain, LLC
Owner Address: 108 N. 00E Rd.
Foosland, IL 61845
Owner Status: Current Owner
Purchase Date: 9/1/2020
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/5/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 3/1/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040083 Three Corners Grain, LLC Current Owner 9/1/2020
U0015848 W. H. Arends Farms, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Dyed Diesel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/9/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 4/9/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1000 3/19/2024 3/19/2025
Overfill Prev Device Overfill Drop Tube Valve 3/10/2023 3/10/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/10/2023 3/10/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found