Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4015557
Status: Active
Facility Name: Pontiac Citgo
Address: 212 S. Mill Street
Pontiac, IL 61764
County: Livingston
Property Parcel: 15-15-22-452-003-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003323
Green Tag Issue Date: 9/13/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Pontiac 66, LLC
Owner Address: 212 S. Mill Street
Pontiac, IL 61764
Owner Status: Current Owner
Purchase Date: 2/8/2023
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/2/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/30/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040861 Pontiac 66, LLC Current Owner 2/8/2023
U0038679 DM Patel, LLC Former Owner 2/10/2017
U0034501 Naqvi, Hameed Former Owner 10/17/2007
U0033157 Mulligan Petro, Inc. Former Owner 6/27/2005
U0029349 Wyllie, John Former Owner 6/27/2005
U0033011 Singh, Dalbir Former Owner
U0010780 Myers, James Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00354-2025UPG Upgrade Approved / Amended 3/25/2025 3/26/2025 9/26/2025 Documents

Notice of Violations (Current)

NOV Number: E0020250782 (Pending)    Issue Date: 3/25/2025    Expiration Date: 5/24/2025    View NOV Form

Tanks Violation
5 Miscellaneous - Sump sensor failed test. Repair or replace.
5, 6, 7 Monthly line interstitial sensor records not available.
5, 6, 7 Required monthly tank leak test records not available.
7 Tank monitor does not appear to function properly and requires maintenance. - ATG is in alarm for tank 7. Repair or replace. Dates are not correct on ATG. Correct the date. Date is reported as 01/24/2036.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
99-2459 12/8/1999 Removal Log 03514-1999REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
99-2459 Eligible 12/15/1999 12/22/1999 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/8/1999
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/15/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/8/1999
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/15/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/8/1999
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/8/1999
OSFM First Notify Date: 11/22/1999 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/15/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 8000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/19/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 8/17/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/17/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/1/2025 4/1/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 with SCALD 1/24/2025 1/24/2026
Overfill Prev Device Ball Float Vent Valve 10/27/2022 10/27/2025
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 10/31/2022 10/31/2025
Leak Detect - Piping Sump Sensor 10/5/2023 10/5/2024
Spill Contain Device Single Wall Spill Bucket 10/31/2022 10/31/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 1/24/2025



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/19/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 8/17/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/17/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/25/2025 3/25/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 with SCALD 1/24/2025 1/24/2026
Overfill Prev Device Ball Float Vent Valve 10/27/2022 10/27/2025
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 10/31/2022 10/31/2025
Leak Detect - Piping Sump Sensor 1/24/2025 1/24/2026
Spill Contain Device Single Wall Spill Bucket 10/31/2022 10/31/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 1/24/2025



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/19/2001 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 8/17/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/17/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/24/2025 1/24/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 with SCALD 1/24/2025 1/24/2026
Overfill Prev Device Ball Float Vent Valve 10/27/2022 10/27/2025
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 10/31/2022 10/31/2025
Leak Detect - Piping Sump Sensor 1/24/2025 1/24/2026
Spill Contain Device Single Wall Spill Bucket Insert 10/31/2022 10/31/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 1/24/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms