Facility Number:
4015466
Status:
Active
Facility Name:
Wyckles Petroleum Mart, Inc. d/b/a Wyckles Fuel Mart
Address:
355 N. Wyckles Rd.
Decatur, IL 62522
County:
Macon
Property Parcel:
06-11-13-226-012
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
AA00982
Green Tag Issue Date:
3/3/2025
Green Tag Expiration Date:
12/31/2027
Owner Details
Owner Name:
Decatur Real Estate Investment, LLC
Owner Address:
955 Malinda Court
Forsyth, IL 62535
Owner Status:
Current Owner
Purchase Date:
5/11/2017
Type of Financial Responsibility:
Letter of Credit
Financial Responsibility Reporting Due Date:
11/4/2025
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
3/3/2025
12/31/2027
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0039036
Decatur Real Estate Investment, LLC
Current Owner
5/11/2017
U0038874
Wyckles Petroleum Mart, Inc.
Former Owner
5/1/2016
U0034184
Sandhu-Decatur LLC - Prairie Midwest
Former Owner
3/1/2007
U0019761
Borchers CC Inc
Former Owner
9/26/1989
U0001982
Brock Carl E
Former Owner
12/31/1967
U0024735
Prairie Midwest Inc
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
982585
10/14/1998
Removal Log
3436-98
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
98-2585
Eligible
11/13/1998
1/4/1999
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/13/1998
OSFM
First Notify Date:
4/11/1986
Abandoned Material:
Current Age:
20
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
11/13/1998
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/13/1998
OSFM
First Notify Date:
4/11/1986
Abandoned Material:
Current Age:
20
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
11/13/1998
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/13/1998
OSFM
First Notify Date:
4/11/1986
Abandoned Material:
Current Age:
20
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
11/13/1998
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/13/1998
OSFM
First Notify Date:
4/11/1986
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
11/13/1998
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
500
Petroleum Use:
Consumptive Use on Premises for Heating
Product:
Heating Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
State
Removed Date:
11/13/1998
OSFM
First Notify Date:
6/3/1992
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
11/13/1998
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
8000
Petroleum Use:
Product:
CERCLA Substance:
Status:
Abandoned in place
CAS Code:
Regulated Status:
Exempt
Removed Date:
OSFM
First Notify Date:
4/11/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
Abandoned Date:
5/1/1978
Install Date:
Red Tag Issue Date:
Last Used Date:
5/1/1978
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
8000
Petroleum Use:
Product:
CERCLA Substance:
Status:
Abandoned in place
CAS Code:
Regulated Status:
Exempt
Removed Date:
OSFM
First Notify Date:
4/11/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
Abandoned Date:
5/1/1978
Install Date:
Red Tag Issue Date:
Last Used Date:
5/1/1978
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
8000
Petroleum Use:
Product:
CERCLA Substance:
Status:
Abandoned in place
CAS Code:
Regulated Status:
Exempt
Removed Date:
OSFM
First Notify Date:
4/11/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
Abandoned Date:
5/1/1978
Install Date:
Red Tag Issue Date:
Last Used Date:
5/1/1978
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 9
Capacity:
250
Petroleum Use:
None
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/13/1998
OSFM
First Notify Date:
4/11/1986
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
11/13/1998
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 10
Capacity:
10000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
1/27/1999
Abandoned Material:
Current Age:
26
Abandoned Date:
Install Date:
10/13/1998
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
10/27/1998
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
12/23/2024
12/23/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
12/23/2024
12/23/2025
Overfill Prev Device
Overfill Alarm
12/19/2022
12/19/2025
Overfill Prev Device
Overfill Drop Tube Valve
12/19/2022
12/19/2025
Piping
Flexible Double Wall
N/A
N/A
Piping
Flex Connector Steel
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
12/19/2022
12/19/2025
Leak Detect - Piping
Sump Sensor
12/23/2024
12/23/2025
Spill Contain Device
Single Wall Spill Bucket
12/19/2022
12/19/2025
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall
Precision Test (Piping)
Pass
12/23/2024
Tank
Fiberglass Single Wall
Precision Test (Tank)
Pass
3/11/2020
Tank Number 11
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
1/27/1999
Abandoned Material:
Current Age:
26
Abandoned Date:
Install Date:
10/13/1998
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
10/27/1998
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
12/23/2024
12/23/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
12/23/2024
12/23/2025
Overfill Prev Device
Overfill Alarm
12/19/2022
12/19/2025
Overfill Prev Device
Overfill Drop Tube Valve
12/19/2022
12/19/2025
Piping
Flexible Double Wall
N/A
N/A
Piping
Flex Connector Steel
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
12/19/2022
12/19/2025
Leak Detect - Piping
Sump Sensor
12/23/2024
12/23/2025
Spill Contain Device
Single Wall Spill Bucket
12/19/2022
12/19/2025
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall
Precision Test (Piping)
Pass
12/23/2024
Tank
Fiberglass Single Wall
Precision Test (Tank)
Pass
3/11/2020
Tank Number 12
Capacity:
6000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
1/27/1999
Abandoned Material:
Current Age:
26
Abandoned Date:
Install Date:
10/13/1998
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
10/27/1998
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
12/23/2024
12/23/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
12/23/2024
12/23/2025
Overfill Prev Device
Overfill Alarm
12/19/2022
12/19/2025
Overfill Prev Device
Overfill Drop Tube Valve
12/19/2022
12/19/2025
Piping
Flexible Double Wall
N/A
N/A
Piping
Flex Connector Steel
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
12/19/2022
12/19/2025
Leak Detect - Piping
Sump Sensor
12/23/2024
12/23/2025
Spill Contain Device
Single Wall Spill Bucket
12/19/2022
12/19/2025
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall
Precision Test (Piping)
Pass
12/23/2024
Tank
Fiberglass Single Wall
Precision Test (Tank)
Pass
3/11/2020
Tank Number 13
Capacity:
4000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
1/27/1999
Abandoned Material:
Current Age:
26
Abandoned Date:
Install Date:
10/13/1998
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
10/27/1998
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
12/23/2024
12/23/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
12/23/2024
12/23/2025
Overfill Prev Device
Overfill Alarm
12/19/2022
12/19/2025
Piping
Flexible Double Wall
N/A
N/A
Piping
Flex Connector Steel
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
12/19/2022
12/19/2025
Leak Detect - Piping
Sump Sensor
12/23/2024
12/23/2025
Spill Contain Device
Single Wall Spill Bucket
12/19/2022
12/19/2025
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall
Precision Test (Piping)
Pass
12/23/2024
Tank
Fiberglass Single Wall
Precision Test (Tank)
Pass
12/17/2020
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 10S
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 9M/10M
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
Name\ID 9S
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found