Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4015448
Status: Active
Facility Name: IL Central School Bus
Address: 1103-1/2 East Croxton Avenue Bloomington, IL 61701
County: McLean
Property Parcel: 21-10-152-013
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: Z004244
Green Tag Issue Date: 10/9/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Illinois Central School Bus LLC
Owner Address: 3033 W. Jefferson Street Suite 220 Joliet, IL 60435
Owner Status: Current Owner
Purchase Date: 3/31/2025
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 7/29/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 10/9/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041486 Illinois Central School Bus LLC Current Owner 3/31/2025
U0030276 First Student, Inc. Former Owner 9/30/2008
U0008224 Kal Leasing Inc Former Owner 12/31/1967
U0028964 First Group America Former Owner
U0022886 Ryder Student Transportation Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
96-1313 7/24/1996 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
96-1313 Eligible 12/31/1996 1/29/1997 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/24/1996
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/24/1996
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/10/1996 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 7/25/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/25/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1000 8/5/2025 8/5/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/5/2025 8/5/2026
Overfill Prev Device Overfill Drop Tube Valve 8/9/2024 8/9/2027
Piping Fiberglass Double Wall N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 8/9/2024 8/9/2027
Leak Detect - Piping Sump Sensor 8/5/2025 8/5/2026
Spill Contain Device Single Wall Spill Bucket 8/9/2024 8/9/2027
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/9/2024 8/9/2027
Leak Detect - Piping Sump Sensor 8/5/2025 8/5/2026

MFD Motorfuel Dispensing Forms

No Forms Found