Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4012004
Status: Active
Facility Name: IDOT Pontiac (334)
Address: 12970 E. 1700 N. Road (Rt. 116 W.)
Pontiac, IL 61764
County: Livingston
Property Parcel: 00000000
Facility Type: State
Owner Type: State
Green Tag Decal: Y004592
Green Tag Issue Date: 11/30/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Illinois Department of Transportation
Owner Address: 2300 S. Dirksen Parkway
Springfield, IL 62764
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 12/27/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 11/30/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0021798 Illinois Department of Transportation Current Owner
U0007414 Illinois Department of Transportation Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/25/1987 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 1/1/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/10/2025 4/10/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4c 4/10/2025 4/10/2026
Overfill Prev Device Overfill Drop Tube Valve 4/10/2025 4/10/2028
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 4/10/2025 4/10/2028
Leak Detect - Piping Non-Discriminating Sump Sensor 6/10/2021 6/10/2022
Leak Detect - Piping Sump Sensor with positive shutdown 4/10/2025 4/10/2026
Spill Contain Device Single Wall Spill Bucket 4/10/2025 4/10/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 4/10/2025



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/25/1987 Abandoned Material:
Current Age: 44 Abandoned Date:
Install Date: 1/1/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/10/2025 4/10/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS - 4c 4/10/2025 4/10/2026
Overfill Prev Device Overfill Drop Tube Valve 4/10/2025 4/10/2028
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 4/10/2025 4/10/2028
Leak Detect - Piping Non-Discriminating Sump Sensor 6/10/2021 6/10/2022
Leak Detect - Piping Sump Sensor with positive shutdown 4/10/2025 4/10/2026
Spill Contain Device Single Wall Spill Bucket 4/10/2025 4/10/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 4/10/2025



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/1/1985
OSFM First Notify Date: 2/25/1987 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 6/1/1985 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/10/2025 4/10/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/10/2025 4/10/2026



Name\ID 2/3

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/10/2025 4/10/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/10/2025 4/10/2026

MFD Motorfuel Dispensing Forms