Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4010596
Status: Closed
Facility Name: Sullivan Marina & Campground LLC
Address: 925 State Highway 32
Sullivan, IL 61951
County: Moultrie
Property Parcel: 08-08-26-000-413
Facility Type: Marina
Owner Type: Private
Green Tag Decal: S005147
Green Tag Issue Date: 7/25/2017
Green Tag Expiration Date: 12/31/2019

Owner Details

Owner Name: Sullivan Marina & Campground LLC
Owner Address: 925 State Highway 32
Sullivan, IL 61951
Owner Status: Current Owner
Purchase Date: 5/22/1995
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/30/2021

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Marina 5/17/2019 12/31/2021

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0024031 Sullivan Marina & Campground LLC Current Owner 5/22/1995
U0023222 Us Army Corps Of Engineers Former Owner 8/4/1994
U0007381 Il Fox Harbor Inc Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
940603 9/14/1994 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20201058 Eligible 1/5/2021 1/5/2021 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/24/2020
OSFM First Notify Date: 4/17/1997 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 5/22/1995 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 5/22/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 5/18/2019 5/18/2022
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/18/2019 5/18/2020
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/18/2019 5/18/2020
Overfill Prev Device Overfill Drop Tube Valve 5/8/2019 5/8/2022
Piping Fiberglass Double Wall N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Sump Sensor 5/18/2019 5/18/2020
Spill Contain Device Single Wall Spill Bucket 5/8/2019 5/8/2022
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 5/18/2019
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 4/25/2009



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/14/1994
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 1/1/1969 Red Tag Issue Date:
Last Used Date: 9/4/1994 Fee Due: $0.00
Product Date: 1/1/1969

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/14/1994
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 1/1/1969 Red Tag Issue Date:
Last Used Date: 9/4/1994 Fee Due: $0.00
Product Date: 1/1/1969

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/14/1994
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 1/1/1969 Red Tag Issue Date:
Last Used Date: 9/1/1993 Fee Due: $0.00
Product Date: 1/1/1969

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 9/14/1994
OSFM First Notify Date: 5/11/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 24 Abandoned Date: 4/1/1976
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: 9/1/1973 Fee Due:
Product Date: 1/1/1970

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 9/14/1994
OSFM First Notify Date: 5/11/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 24 Abandoned Date: 4/1/1976
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: 9/1/1973 Fee Due:
Product Date: 1/1/1970

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID East

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A



Name\ID Middle

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A



Name\ID West

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found