Facility Details
Facility Number:
4009767
Status:
Active
Facility Name:
The Kraft Heinz Company
Address:
1701 W. Bradley Ave.
Champaign, IL 61821
County:
Champaign
Property Parcel:
Facility Type:
Industrial / Manufacturing
Owner Type:
Private
Green Tag Decal:
Z000979
Green Tag Issue Date:
6/4/2024
Green Tag Expiration Date:
12/31/2026
Owner Details
Owner Name:
The Kraft Heinz Company
Owner Address:
1701 W. Bradley Ave.
Champaign, IL 61821
Owner Status:
Current Owner
Purchase Date:
11/1/1996
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
3/24/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Fleet
6/4/2024
12/31/2026
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0008630
The Kraft Heinz Company
Current Owner
11/1/1996
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
913083
10/28/1991
Removal Log
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
20000
Petroleum Use:
Product:
Fuel Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/28/1991
OSFM
First Notify Date:
9/16/1991
Abandoned Material:
Current Age:
23
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
20000
Petroleum Use:
Product:
Fuel Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/28/1991
OSFM
First Notify Date:
9/16/1991
Abandoned Material:
Current Age:
23
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
20000
Petroleum Use:
Product:
Fuel Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/28/1991
OSFM
First Notify Date:
9/16/1991
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
20000
Petroleum Use:
Product:
Fuel Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/28/1991
OSFM
First Notify Date:
9/16/1991
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
20000
Petroleum Use:
Product:
Fuel Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/28/1991
OSFM
First Notify Date:
9/16/1991
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
15036
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
2/19/1992
OSFM
First Notify Date:
7/7/1986
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
7/1/1979
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 9
Capacity:
551
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
2/26/1992
OSFM
First Notify Date:
7/7/1986
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 10
Capacity:
15000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
7/7/1986
Abandoned Material:
Current Age:
44
Abandoned Date:
Install Date:
5/5/1981
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Sacrificial Anode Cathodic Protection
4/21/2025
4/21/2028
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
4/21/2025
4/21/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus
4/21/2025
4/21/2026
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
4/21/2025
4/21/2026
Overfill Prev Device
Overfill Alarm
4/21/2025
4/21/2028
Overfill Prev Device
Overfill Drop Tube Valve
4/21/2025
4/21/2028
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
4/21/2025
4/21/2028
Leak Detect - Piping
Sump Sensor
4/21/2025
4/21/2026
Piping
Single Wall Transition Sump
4/21/2025
4/21/2028
Leak Detect - Piping
Sump Sensor
4/21/2025
4/21/2026
Spill Contain Device
Single Wall Spill Bucket
4/21/2025
4/21/2028
Tank
STIP3 Double Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Double Wall
Precision Test (Piping)
Pass
4/21/2025
Leak Detect - Piping
Non-Discriminating Sump Sensor
Sensor Functional
Pass
11/6/2009
Tank Number 11
Capacity:
9765
Petroleum Use:
Product:
Ethyl Acetate
CERCLA Substance:
Ethyl Acetate
Status:
Abandoned in place
CAS Code:
141-78-6
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
7/7/1986
Abandoned Material:
Inert material mixed with portland cement
Current Age:
14
Abandoned Date:
8/28/1997
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 12
Capacity:
100
Petroleum Use:
Product:
Methanol
CERCLA Substance:
Methanol
Status:
Unknown
CAS Code:
67-56-1
Regulated Status:
Non-Regulated
Removed Date:
OSFM
First Notify Date:
7/7/1986
Abandoned Material:
Current Age:
36
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
12/31/1996
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 13
Capacity:
20000
Petroleum Use:
Product:
Denatured Alcohol
CERCLA Substance:
Denatured Alcohol and Ethanol
Status:
Unknown
CAS Code:
Regulated Status:
Non-Regulated
Removed Date:
OSFM
First Notify Date:
10/23/1997
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
2/17/1997
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
8/8/1997
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
Leak Detect - Piping
Sump Sensor
Leak Detect - Piping
Sump Sensor
Leak Detect - Tank
Automatic Tank Gauging
Leak Detect - Tank
Hydrostatic Reservoir Interstitial Monitoring Sensors
Overfill Prev Device
Overfill Alarm
Piping
Fiberglass Double Wall
N/A
N/A
Piping
Fiberglass Secondary Containment
N/A
N/A
Piping
Stainless Steel Single Wall Piping
N/A
N/A
Piping
Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Field Constructed
N/A
N/A
Tank
Fiberglass Double Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 14
Capacity:
20000
Petroleum Use:
Product:
Heating Oil
CERCLA Substance:
Status:
Abandoned in place
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/24/1994
Abandoned Material:
Inert material mixed with portland cement
Current Age:
Abandoned Date:
10/29/1991
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 15
Capacity:
20000
Petroleum Use:
Product:
Heating Oil
CERCLA Substance:
Status:
Abandoned in place
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
5/24/1994
Abandoned Material:
Inert material mixed with portland cement
Current Age:
Abandoned Date:
2/19/1992
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
Name\ID 1
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Installed
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found