Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4009444
Status: Active
Facility Name: Villa Grove School District 302
Address: North Route 130 Villa Grove, IL 61956
County: Douglas
Property Parcel:
Facility Type: School/College
Owner Type: Other Local
Green Tag Decal: BB03775
Green Tag Issue Date: 3/17/2026
Green Tag Expire Date: 12/31/2028
MFD Type: Fleet

Owner Details

Owner Name: Villa Grove School District 302
Owner Address: 400 N. Sycamore Villa Grove, IL 61956
Owner Status: Current Owner
Purchase Date: 9/4/1995
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/8/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0015730 Villa Grove School District 302 Current Owner 9/4/1995

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
95-1278 Eligible 1/8/1996 1/26/1996 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/20/1995
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 2

Capacity: 500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/20/1995
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 3

Capacity: 600 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/25/1995 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 9/26/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 3/26/2026 3/26/2027
Overfill Prev Device Overfill Drop Tube Valve 3/31/2025 3/31/2028
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 3/31/2025 3/31/2028
Tank Fiberglass Double Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank SIR and Prec Tightness Testing Precision Test (Tank) Pass 2/19/2013



Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/25/1995 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 9/26/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 3/26/2026 3/26/2027
Overfill Prev Device Overfill Drop Tube Valve 3/31/2025 3/31/2028
Piping Fiberglass Double Wall Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 3/31/2025 3/31/2028
Tank Fiberglass Double Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank SIR and Prec Tightness Testing Precision Test (Tank) Pass 2/19/2013

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms