Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4005029
Status: Active
Facility Name: Carlock Auto Servicenter
Address: 302 W. Washington
Carlock, IL 61725
County: McLean
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X002775
Green Tag Issue Date: 12/8/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: William Leenerman
Owner Address: 1114 N. Main Street
Normal, IL 61761
Owner Status: Current Owner
Purchase Date: 10/1/2013
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/6/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 10/20/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037133 Leenerman, William Current Owner 10/1/2013
U0016748 Yoder , Roger Former Owner 12/4/1992

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
98-2208 9/4/1998 Removal Log
982208 9/4/1998 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
92-3353 Eligible 9/23/1998 11/4/1998 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/4/1998
OSFM First Notify Date: 3/21/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 6/15/1998 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/4/1998
OSFM First Notify Date: 3/21/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 6/1/1992 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/22/1993 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 12/4/1992 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 12/5/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/26/2024 2/26/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/26/2024 2/26/2025
Overfill Prev Device Ball Float Vent Valve 2/26/2024 2/26/2027
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/26/2024 2/26/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test Pass 3/3/2021



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/22/1993 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 12/4/1992 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 12/5/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/26/2024 2/26/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/26/2024 2/26/2025
Overfill Prev Device Ball Float Vent Valve 2/26/2024 2/26/2027
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/26/2024 2/26/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 10000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/22/1993 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 12/4/1992 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 12/5/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/26/2024 2/26/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/26/2024 2/26/2025
Overfill Prev Device Ball Float Vent Valve 2/26/2024 2/26/2027
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/26/2024 2/26/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/22/1993 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 12/4/1992 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 12/5/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/26/2024 2/26/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/26/2024 2/26/2025
Overfill Prev Device Ball Float Vent Valve 2/26/2024 2/26/2027
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/26/2024 2/26/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/4/1998
OSFM First Notify Date: 3/21/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 6/1/1998 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 11

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/4/1998
OSFM First Notify Date: 3/21/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 6/1/1998 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 12

Capacity: 8300 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/4/1998
OSFM First Notify Date: 3/21/1986 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 6/1/1998 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/26/2024 2/26/2027
Leak Detect - Piping Sump Sensor 2/26/2024 2/26/2025

MFD Motorfuel Dispensing Forms

No Forms Found