Facility Details
Facility Number:
4002108
Status:
Closed
Facility Name:
Gas 4 Less
Address:
2021 Charleston Avenue
Mattoon, IL 61938
County:
Coles
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
G000819
Green Tag Issue Date:
10/23/2007
Green Tag Expiration Date:
12/31/2008
Owner Details
Owner Name:
Ken Diepholz
Owner Address:
P.O. Box 909
Mattoon, IL 61938
Owner Status:
Current Owner
Purchase Date:
1/1/1965
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
7/10/2009
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
10/23/2007
12/31/2008
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0020680
Diepholz, Ken
Current Owner
1/1/1965
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
08-1651
11/12/2008
Removal Log
01747-2008REM
08-1651
3/26/2009
Removal Log
01747-2008REM
08-1651
4/1/2009
Removal Log
00351-2009REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
04-0027
Eligible
3/29/2004
4/15/2004
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/12/2008
OSFM
First Notify Date:
3/19/1986
Abandoned Material:
Current Age:
32
Abandoned Date:
Install Date:
1/1/1976
Red Tag Issue Date:
Last Used Date:
4/8/2008
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Impressed Current Cathodic Protection
Leak Detect - Piping
Pressurized Line Leak Detection
Leak Detect - Tank
Automatic Tank Gauging
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Stainless Steel Single Wall Piping
N/A
N/A
Piping
Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Manhole Field Constructed
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/12/2008
OSFM
First Notify Date:
3/19/1986
Abandoned Material:
Current Age:
32
Abandoned Date:
Install Date:
1/1/1976
Red Tag Issue Date:
Last Used Date:
4/8/2008
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
Corrosion Prot - Tank
Impressed Current Cathodic Protection
Leak Detect - Tank
Automatic Tank Gauging Incon TS 1000
Overfill Prev Device
Overfill Drop Tube Valve
Spill Contain Device
Single Wall Spill Bucket
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
4000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/12/2008
OSFM
First Notify Date:
3/19/1986
Abandoned Material:
Current Age:
30
Abandoned Date:
Install Date:
1/1/1978
Red Tag Issue Date:
Last Used Date:
6/1/2006
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
20000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
3/26/2009
OSFM
First Notify Date:
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
14000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
3/26/2009
OSFM
First Notify Date:
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
1000
Petroleum Use:
Product:
Unknown
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Exempt
Removed Date:
4/1/2009
OSFM
First Notify Date:
Abandoned Material:
Current Age:
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
12/31/1973
Fee Due:
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found