Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4002024
Status: Closed
Facility Name: Dixie Pit Stop
Address: 445 N. Vermilion
Danville, IL 61832
County: Vermilion
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Q003298
Green Tag Issue Date: 10/13/2015
Green Tag Expiration Date: 12/31/2017

Owner Details

Owner Name: Alex Ikbariah
Owner Address: P.O. Box 10908
Jackson, TN 38308
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 11/2/2017

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 9/29/2015 12/31/2017

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036240 Ikbariah, Alex Current Owner
U0033211 YAZ Gas, Inc. Former Owner 1/11/2006
U0008510 Bob Kirts Marathon Former Owner 5/1/1982

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
17-0104 3/7/2017 Removal Log 00173-2017REM
17-0104 3/8/2017 Removal Log 00173-2017REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20170104 Eligible 3/7/2017 3/9/2017 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/7/2017
OSFM First Notify Date: 2/11/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 2/28/1976 Red Tag Issue Date:
Last Used Date: 4/1/2013 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 7/11/2012 7/11/2013
Corrosion Prot - Tank Lining Materials Internal 2/27/2012 2/27/2017
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/26/2013 3/26/2014
Leak Detect - Tank SIR and Prec Tightness Testing SIR International Inc.
Overfill Prev Device Overfill Drop Tube Valve
Piping Galvanized Steel Single Wall Piping N/A N/A
Spill Contain Device Double Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank SIR and Prec Tightness Testing SIR International Inc. Precision Test (Tank) Pass 3/26/2013



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/7/2017
OSFM First Notify Date: 2/11/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 2/28/1976 Red Tag Issue Date:
Last Used Date: 3/15/2016 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 6/11/2015 6/11/2016
Corrosion Prot - Tank Lining Materials Internal 2/27/2012 2/27/2017
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/10/2015 3/10/2016
Leak Detect - Tank SIR and Prec Tightness Testing SIR International Inc.
Overfill Prev Device Overfill Drop Tube Valve
Piping Galvanized Steel Single Wall Piping N/A N/A
Spill Contain Device Double Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank SIR and Prec Tightness Testing SIR International Inc. Precision Test (Tank) Pass 3/10/2015



Tank Number 3

Capacity: 3000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/8/2017
OSFM First Notify Date: 2/11/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 2/28/1976 Red Tag Issue Date:
Last Used Date: 3/15/2016 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 6/11/2015 6/11/2016
Corrosion Prot - Tank Lining Materials Internal 2/27/2012 2/27/2017
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/10/2015 3/10/2016
Leak Detect - Tank SIR and Prec Tightness Testing SIR International Inc.
Overfill Prev Device Overfill Drop Tube Valve
Piping Galvanized Steel Single Wall Piping N/A N/A
Spill Contain Device Double Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank SIR and Prec Tightness Testing SIR International Inc. Precision Test (Tank) Pass 3/10/2015



Tank Number 4

Capacity: 3000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/8/2017
OSFM First Notify Date: 2/11/1986 Abandoned Material:
Current Age: 41 Abandoned Date:
Install Date: 2/28/1976 Red Tag Issue Date:
Last Used Date: 3/15/2016 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 6/11/2015 6/11/2016
Corrosion Prot - Tank Lining Materials Internal 2/27/2012 2/27/2017
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/10/2015 3/10/2016
Leak Detect - Tank SIR and Prec Tightness Testing SIR International Inc.
Overfill Prev Device Overfill Drop Tube Valve
Piping Galvanized Steel Single Wall Piping N/A N/A
Spill Contain Device Double Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank SIR and Prec Tightness Testing SIR International Inc. Precision Test (Tank) Pass 3/10/2015



Tank Number 5

Capacity: 1000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 5/3/2017
OSFM First Notify Date: 8/2/1991 Abandoned Material: Inert material mixed with portland cement
Current Age: 22 Abandoned Date: 4/16/1991
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 1000 Petroleum Use: None
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/3/2017
OSFM First Notify Date: 2/18/1992 Abandoned Material: Inert material mixed with portland cement
Current Age: Abandoned Date: 9/5/2000
Install Date: Red Tag Issue Date:
Last Used Date: 12/22/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 300 Petroleum Use:
Product: White Gas CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 5/3/2017
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found