Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4001414
Status: Active
Facility Name: XPO Logistics Freight, Inc. - XDV
Address: 712 W. Ross Lane
Danville, IL 61832
County: Vermilion
Property Parcel: 23-30-100-002
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Z003643
Green Tag Issue Date: 7/8/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: XPO Logistics Freight, Inc.
Owner Address: 2211 Old Earhart Rd., Suite 100
Ann Arbor, MI 48105
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/14/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 7/8/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038082 XPO Logistics Freight, Inc. Current Owner
U0003305 Con-way Freight, Inc. Former Owner 11/20/1987
U0011456 P I E Nationwide, Inc. Former Owner 12/31/1967
U0026176 CNF Properties, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
98-1847 7/28/1998 Removal Log 0479-98

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
98-1847 Eligible 10/2/2007 10/17/2007 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/28/1998
OSFM First Notify Date: 3/3/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: 7/27/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/28/1998
OSFM First Notify Date: 3/3/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: 7/27/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/28/1998
OSFM First Notify Date: 3/3/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: 7/27/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/22/1998 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 7/30/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/30/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/28/2024 6/28/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 6/28/2024 6/28/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/28/2024 6/28/2025
Overfill Prev Device Overfill Alarm 1/12/2023 1/12/2026
Overfill Prev Device Overfill Drop Tube Valve 1/20/2023 1/20/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 7/13/2023 7/13/2026
Leak Detect - Piping Sump Sensor 6/28/2024 6/28/2025
Spill Contain Device Single Wall Spill Bucket 6/28/2024 6/28/2027
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 6/28/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found