Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4001363
Status: Active
Facility Name: South Central FS, Inc. - Sullivan C Store
Address: 305 S. Hamilton Street
Sullivan, IL 61951
County: Moultrie
Property Parcel: 08-08-02-451-006
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z002583
Green Tag Issue Date: 9/27/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: South Central FS, Inc.
Owner Address: 405 S. Banker Street
P.O. Box 629
Effingham, IL 62401
Owner Status: Current Owner
Purchase Date: 7/23/2019
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 2/27/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 9/27/2024 12/31/2026
Unattended Self Service 6/16/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0005048 South Central FS, Inc. Current Owner 7/23/2019
U0035721 E-K Petroleum, LLC Former Owner 10/1/2009
U0033953 Amin, Kauserul Former Owner 11/27/2005
U0032620 Gasmarts of Illinois, LLC Former Owner 11/19/2004
U0008410 Kerr Mcgee Refining Corp Former Owner 12/31/1967
U0006126 Green Oil Company Former Owner
U0006127 Green Oil Co Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00476-2025LIN Lining Inspection Approved / Issued 4/22/2025 4/22/2025 10/22/2025 Documents

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/9/1990 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 10/22/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/22/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/30/2023 5/30/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/29/2024 5/29/2025
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Plus with CSLD 5/29/2024 5/29/2025
Overfill Prev Device Ball Float Vent Valve 5/31/2023 5/31/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/29/2024 5/29/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 5/29/2024



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/9/1990 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 10/22/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/22/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/30/2023 5/30/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal Armor Shield TL 300M 4/21/2020 4/21/2025
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/29/2024 5/29/2025
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Plus with CSLD 5/29/2024 5/29/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/29/2024 5/29/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 5/29/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 4/22/2020



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/25/1989
OSFM First Notify Date: 3/3/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: 1/1/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/25/1989
OSFM First Notify Date: 3/3/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: 1/1/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 300 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 7/1/1985
OSFM First Notify Date: 3/3/1986 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: 1/1/1985 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
4001363 South Central FS, Inc. - Sullivan C Store Sullivan 05/24/2022 Letter Form
4001363 South Central FS, Inc. - Sullivan C Store Sullivan 04/04/2022 Letter Form