Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3044568
Status: Active
Facility Name: Hy-Vee Gas
Address: 500 17th Avenue Drive Silvis, IL 61282
County: Rock Island
Property Parcel: 18-06-402-002
Facility Type: Attended Self-Service/Unattended Self-Service
Owner Type: Private
Green Tag Decal: Z000407
Green Tag Issue Date: 6/18/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service; Unattended Self Service

Owner Details

Owner Name: Hy-Vee, Inc.
Owner Address: 5820 Westown Parkway West Des Moines, IA 50266
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/29/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030721 Hy-Vee, Inc. Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020261378 (Pending)    Issue Date: 5/27/2026    Expiration Date: 7/26/2026    View NOV Form

Tanks Violations
1, 2 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - STP ground cover containment supports deteriorated repair or replace to allow for inspection. Ground cover not removable.
4 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - STP ground cover handle deteriorated repair or replace to allow for inspection.
1, 2, 3 Line interstitial sensors have been raised and rendered inoperational. - Dispenser 7/8, 9/10 UDC sensors
3 Line interstitial sensors have been raised and rendered inoperational. - STP sump sensors
4 Line interstitial sensors have been raised and rendered inoperational. - Dispenser 7/8, 9/10 UDC sensors
5 Line interstitial sensors have been raised and rendered inoperational. - STP sump sensors
Facility Missing copy of emergency instructions or emergency procedures plan - Forms can be found at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms
Facility Missing copy of written UST facility operation & maintenance plan - Forms can be found at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms
Facility Missing list of designated Class A/B & C Operators - Forms can be found at: https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms
3, 4, 5 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
3 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress. - STP sump

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 14000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/22/2010 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 11/3/2009 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/22/2009

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/25/2025 9/25/2026
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 9/25/2025 9/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/25/2025 9/25/2026
Overfill Prev Device Overfill Drop Tube Valve 9/25/2025 9/25/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 10/20/2023 10/20/2026
Leak Detect - Piping Sump Sensor 9/25/2025 9/25/2026
Spill Contain Device Single Wall Spill Bucket 10/20/2023 10/20/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 9/25/2025



Tank Number 2

Capacity: 14000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/22/2010 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 11/3/2009 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/22/2009

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 9/25/2025 9/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/25/2025 9/25/2026
Overfill Prev Device Overfill Drop Tube Valve 9/25/2025 9/25/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 10/20/2023 10/20/2026
Leak Detect - Piping Sump Sensor 9/25/2025 9/25/2026
Spill Contain Device Single Wall Spill Bucket 10/20/2023 10/20/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 9/25/2025



Tank Number 3

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/22/2010 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 11/3/2009 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/22/2009

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/25/2025 9/25/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 9/25/2025 9/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/25/2025 9/25/2026
Overfill Prev Device Overfill Drop Tube Valve 9/25/2025 9/25/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 10/20/2023 10/20/2026
Leak Detect - Piping Sump Sensor 9/25/2025 9/25/2026
Spill Contain Device Single Wall Spill Bucket 10/20/2023 10/20/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/22/2010 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 11/3/2009 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/22/2009

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/25/2025 9/25/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 9/25/2025 9/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/25/2025 9/25/2026
Overfill Prev Device Overfill Drop Tube Valve 9/25/2025 9/25/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 10/20/2023 10/20/2026
Leak Detect - Piping Sump Sensor 9/25/2025 9/25/2026
Spill Contain Device Single Wall Spill Bucket 10/20/2023 10/20/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/22/2010 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 11/3/2009 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/22/2009

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/25/2025 9/25/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 9/25/2025 9/25/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/25/2025 9/25/2026
Overfill Prev Device Overfill Drop Tube Valve 9/25/2025 9/25/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 10/20/2023 10/20/2026
Leak Detect - Piping Sump Sensor 9/25/2025 9/25/2026
Spill Contain Device Single Wall Spill Bucket 10/20/2023 10/20/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/20/2023 10/20/2026
Leak Detect - Piping Sump Sensor 9/25/2025 9/25/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/20/2023 10/20/2026
Leak Detect - Piping Sump Sensor 9/25/2025 9/25/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/20/2023 10/20/2026
Leak Detect - Piping Sump Sensor 9/25/2025 9/25/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/20/2023 10/20/2026
Leak Detect - Piping Sump Sensor 9/25/2025 9/25/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/20/2023 10/20/2026
Leak Detect - Piping Sump Sensor 9/25/2025 9/25/2026

MFD Motorfuel Dispensing Forms