Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3041637
Status: Active
Facility Name: Hy-Vee Gas
Address: 4218 Avenue of the Cities Moline, IL 61265
County: Rock Island
Property Parcel:
Facility Type: Attended Self-Service/Unattended Self-Service
Owner Type: Private
Green Tag Decal: Y001620
Green Tag Issue Date: 12/27/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Hy-Vee, Inc.
Owner Address: 5820 Westown Parkway West Des Moines, IA 50266
Owner Status: Current Owner
Purchase Date: 1/8/2004
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 9/13/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 12/27/2023 12/31/2025
Unattended Self Service 4/29/2021 12/31/2023

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030721 Hy-Vee, Inc. Current Owner 1/8/2004

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251889 (Pending)    Issue Date: 7/25/2025    Expiration Date: 9/23/2025    View NOV Form

Tanks Violations
1, 2, 3 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - STP's supports
1, 3, 4 Spill prevention equipment device is in disrepair and requires replacement. - #4 ground cover damaged - repair or replace. #1 & # 3 in disrepair requires replacement.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Non Ethanol CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/24/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/8/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/8/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/25/2025 4/25/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 4/25/2025 4/25/2026
Overfill Prev Device Overfill Drop Tube Valve 5/7/2024 5/7/2027
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 5/7/2024 5/7/2027
Leak Detect - Piping Sump Sensor 4/25/2025 4/25/2026
Spill Contain Device Single Wall Spill Bucket 5/7/2024 5/7/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/24/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/8/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/8/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/25/2025 4/25/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 4/25/2025 4/25/2026
Overfill Prev Device Overfill Drop Tube Valve 5/7/2024 5/7/2027
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 5/7/2024 5/7/2027
Leak Detect - Piping Sump Sensor 4/25/2025 4/25/2026
Spill Contain Device Single Wall Spill Bucket 5/7/2024 5/7/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 14000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/24/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/8/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/8/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/25/2025 4/25/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 4/25/2025 4/25/2026
Overfill Prev Device Overfill Drop Tube Valve 5/7/2024 5/7/2027
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 5/7/2024 5/7/2027
Leak Detect - Piping Sump Sensor 4/25/2025 4/25/2026
Spill Contain Device Single Wall Spill Bucket 5/7/2024 5/7/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/24/2004 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/8/2004 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/8/2004

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/25/2025 4/25/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 4/25/2025 4/25/2026
Overfill Prev Device Overfill Drop Tube Valve 5/7/2024 5/7/2027
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 5/7/2024 5/7/2027
Leak Detect - Piping Sump Sensor 4/25/2025 4/25/2026
Spill Contain Device Single Wall Spill Bucket 5/7/2024 5/7/2027
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found