Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3035914
Status: Active
Facility Name: Big 10 Mart #21
Address: 1301 13th Street
East Moline, IL 61244
County: Rock Island
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001388
Green Tag Issue Date: 11/3/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Molo Oil Company
Owner Address: 123 Southern Ave.
Dubuque, IA 52003
Owner Status: Current Owner
Purchase Date: 10/3/1997
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/28/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 11/3/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0010513 Molo Oil Company Current Owner 10/3/1997

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00561-2025CAT Cathodic Protection Approved / Issued 5/8/2025 5/8/2025 11/10/2025 Documents

Notice of Violations (Current)

NOV Number: E0020250647 (Pending)    Issue Date: 3/12/2025    Expiration Date: 5/11/2025    View NOV Form

Tanks Violation
1 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Square ground covers damaged and missing containment support components.
1 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - STP ground covers containment support components deteriorated/ missing. Repair to allow for inspection.
2, 3 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Square ground covers damaged and missing containment support components.
3 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - STP ground covers containment support components deteriorated/ missing. Repair to allow for inspection.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/15/1997 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 10/1/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/13/2024 9/13/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 9/13/2024 9/13/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/13/2024 9/13/2025
Overfill Prev Device Overfill Drop Tube Valve 7/17/2023 7/17/2026
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor 9/13/2024 9/13/2025
Spill Contain Device Double Wall Spill Bucket 7/17/2023 7/17/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 9/13/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 6/20/2022



Tank Number 2

Capacity: 8200 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/15/1997 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 10/1/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/13/2024 9/13/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 9/13/2024 9/13/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/13/2024 9/13/2025
Overfill Prev Device Overfill Drop Tube Valve 7/17/2023 7/17/2026
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor 9/13/2024 9/13/2025
Spill Contain Device Single Wall Spill Bucket 7/17/2023 7/17/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 9/13/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 6/20/2022



Tank Number 3

Capacity: 8200 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/15/1997 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 10/1/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/13/2024 9/13/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 9/13/2024 9/13/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/13/2024 9/13/2025
Overfill Prev Device Overfill Drop Tube Valve 7/17/2023 7/17/2026
Piping Flexible Double Wall A.P.T. Poly Tech N/A N/A
Piping Single Wall STP/Tanktop Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor 9/13/2024 9/13/2025
Spill Contain Device Double Wall Spill Bucket 7/17/2023 7/17/2026
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech Precision Test (Piping) Pass 9/13/2024
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 6/20/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found