Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3035522
Status: Active
Facility Name: Santok #3, Inc.
Address: 12200 North Brentfield Road, Suite 6
Dunlap, IL 61525
County: Peoria
Property Parcel: 09-20-152-022
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA00527
Green Tag Issue Date: 3/21/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Jay Ambe Management, LLC
Owner Address: 3209 W. Cypress Creek Drive
Dunlap, IL 61611
Owner Status: Current Owner
Purchase Date: 2/7/2020
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 3/10/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/23/2024 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040179 Jay Ambe Management, LLC Current Owner 2/7/2020
U0039309 Montecito Management Company, LLC Former Owner 12/1/2001
U0025424 Lake Of The Woods Ltd Prtnshp Former Owner 7/31/1998
U0031578 J & D Meyer Ltd. Former Owner
U0012621 Meyers Express / John Meyer Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/10/1998 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 7/31/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/31/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/27/2022 12/27/2025
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/5/2025 2/5/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/12/2025 3/12/2026
Overfill Prev Device Overfill Drop Tube Valve 3/12/2025 3/12/2028
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/12/2025 3/12/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test (Piping) Pass 2/5/2025



Tank Number 2

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/10/1998 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 7/31/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/31/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/27/2022 12/27/2025
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/5/2025 2/5/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/12/2025 3/12/2026
Overfill Prev Device Overfill Drop Tube Valve 3/12/2025 3/12/2028
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/12/2025 3/12/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test (Piping) Pass 2/5/2025



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/10/1998 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 7/31/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/31/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/27/2022 12/27/2025
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/5/2025 2/5/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/12/2025 3/12/2026
Overfill Prev Device Overfill Drop Tube Valve 3/12/2025 3/12/2028
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/12/2025 3/12/2028
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test (Piping) Pass 2/5/2025
Piping Stainless Steel Single Wall Piping Precision Test (Piping) Pass 12/4/2020

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found