Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3032054
Status: Active
Facility Name: Kwik Shop
Address: 118 W. Court Cambridge, IL 61238
County: Henry
Property Parcel: 18-07-404-021
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001603
Green Tag Issue Date: 10/18/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Karnal, Inc.
Owner Address: 118 W. Court Cambridge, IL 61238
Owner Status: Current Owner
Purchase Date: 4/29/2021
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 2/1/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 10/18/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040238 Karnal, Inc. Current Owner 4/29/2021
U0020533 Kwik Shop & Go Inc Former Owner 12/26/1987

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251769 (Pending)    Issue Date: 7/14/2025    Expiration Date: 9/12/2025    View NOV Form

Tanks Violations
Facility Fire Extinguishers - Past due for annual testing - Fuel Island Extinguisher

NOV Number: E0020251770 (Pending)    Issue Date: 7/14/2025    Expiration Date: 9/12/2025    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
2 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Ground cover missing handle - repair or replace handle to allow for inspection.
2 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Support for ground cover serverly damaged - repair or replace to allow for inspection.
1, 2 Flex connector sacrificial anode system not tested (required every 3 years) - Test anodes and replace as needed
Facility Missing copies of Annual Walkthrough Inspection Report.
Facility Operations & Maintenance plan missing required frequencies - Paperwork on site not filled out
1, 2 Piping sacrificial anode system not tested (required every 3 years).
1, 2 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection).
1 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
1, 2 Tank sacrificial anode system not tested (Required every 3 years).

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8200 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/3/1993 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 11/20/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/20/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 8/4/2025 8/4/2028
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 8/4/2025 8/4/2028
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 8/4/2025 8/4/2028
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 8/4/2025 8/4/2028
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/3/2025 2/3/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 1000 2/3/2025 2/3/2026
Overfill Prev Device Overfill Drop Tube Valve 1/26/2023 1/26/2026
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/26/2023 1/26/2026
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 2/3/2025



Tank Number 2

Capacity: 8200 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/3/1993 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 11/20/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/20/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 8/4/2025 8/4/2028
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 8/4/2025 8/4/2028
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 8/4/2025 8/4/2028
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 8/4/2025 8/4/2028
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/3/2025 2/3/2026
Leak Detect - Tank Automatic Tank Gauging Incon TS 1000 2/3/2025 2/3/2026
Overfill Prev Device Overfill Drop Tube Valve 1/26/2023 1/26/2026
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/26/2023 1/26/2026
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test (Piping) Pass 2/3/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found