Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3018692
Status: Closed
Facility Name: Ameren Illinois Persimmon
Address: 1100 Monarch Street Peoria, IL 61602
County: Peoria
Property Parcel: 18-16-104-007
Facility Type: Utility
Owner Type: Private
Green Tag Decal: U005295
Green Tag Issue Date: 1/23/2020
Green Tag Expire Date: 9/13/2021
MFD Type: N/A

Owner Details

Owner Name: Ameren Illinois
Owner Address: 300 Liberty Street Peoria, IL 61602
Owner Status: Current Owner
Purchase Date: 10/1/2010
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/1/2022

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038114 Ameren Illinois Current Owner 10/1/2010
U0002654 Central Illinois Light Company Former Owner 1/1/1953

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
00-0243 3/15/2000 Removal Log 00395-2000REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
00-0243 Eligible 3/10/2000 3/16/2000 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 17

Capacity: 2500 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/14/2021
OSFM First Notify Date: 3/27/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 1/1/1983 Red Tag Issue Date:
Last Used Date: 9/11/2020 Fee Due: $0.00
Product Date: 1/1/1983

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/21/2019 11/21/2020
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 11/21/2019 11/21/2020
Overfill Prev Device Overfill Drop Tube Valve 11/21/2019 11/21/2022
Piping Fiberglass Double Wall Ameron Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 11/21/2019 11/21/2022
Leak Detect - Piping Sump Sensor 11/21/2019 11/21/2022
Spill Contain Device Single Wall Spill Bucket 11/21/2019 11/21/2022
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 11/21/2019
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 12/1/2008



Tank Number 18

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 3/15/2000
OSFM First Notify Date: 3/27/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/1/1979 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1979

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 19

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/5/1995
OSFM First Notify Date: 3/27/1986 Abandoned Material:
Current Age: 42 Abandoned Date:
Install Date: 1/1/1953 Red Tag Issue Date:
Last Used Date: 2/1/1990 Fee Due: $0.00
Product Date: 1/1/1953

Equipment Information

No Equipment Listed


Additional Tests

No Tests Listed




Tank Number 36

Capacity: 500 Petroleum Use: None
Product: Used Oil CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/21/1988 Abandoned Material: Inert material mixed with portland cement
Current Age: 45 Abandoned Date: 12/14/2021
Install Date: 1/1/1981 Red Tag Issue Date:
Last Used Date: 9/11/2020 Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Gravity Feed Not applicable Not applicable
Leak Detect - Tank 110 - 600 gallons Manual Tank Gauging Not applicable Not applicable
Overfill Prev Device Less than 25 gallon fills Not applicable Not applicable
Piping Fiberglass Double Wall Ameron Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 11/21/2019 11/21/2022
Leak Detect - Piping Sump Sensor 11/21/2019 11/21/2022
Spill Contain Device Field Constructed less than 25 gallon fills Not applicable Not applicable
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Spill Contain Device Field Constructed less than 25 gallon fills Functional Pass 11/21/2019

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found