Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3018687
Status: Inactive
Facility Name: E. D. Edwards Energy Center
Address: 7800 S. Cilco Lane
Bartonville, IL 61607
County: Peoria
Property Parcel: 2014200007
Facility Type: Industrial / Manufacturing
Owner Type: Private
Green Tag Decal: X003618
Green Tag Issue Date: 8/31/2022
Green Tag Expiration Date: 2/21/2024

Owner Details

Owner Name: Illinois Power Resources Generating, LLC
Owner Address: 1500 Eastport Plaza Drive
Collinsville, IL 62234
Owner Status: Current Owner
Purchase Date: 12/2/2013
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 2/12/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 8/31/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037142 Illinois Power Resources Generating, LLC Current Owner 12/2/2013
U0031792 Ameren / Cilco Former Owner
U0002654 Central Illinois Light Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 7

Capacity: 2000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/21/2000
OSFM First Notify Date: 3/21/1986 Abandoned Material:
Current Age: 18 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/21/1986 Abandoned Material:
Current Age: 46 Abandoned Date:
Install Date: 3/21/1978 Red Tag Issue Date:
Last Used Date: 2/2/2023 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/16/2022 6/16/2023
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j with CSLD 6/16/2022 6/16/2023
Overfill Prev Device Overfill Drop Tube Valve 6/9/2021 6/9/2024
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 6/9/2021 6/9/2024
Leak Detect - Piping Sump Sensor 6/16/2022 6/16/2023
Spill Contain Device Single Wall Spill Bucket 6/9/2021 6/9/2024
Tank Fiberglass Single Wall Owens Corning N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 20000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Condemned Tank CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/24/2008 Abandoned Material:
Current Age: 56 Abandoned Date:
Install Date: 12/1/1967 Red Tag Issue Date:
Last Used Date: 1/24/2023 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Other Aboveground Piping N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 6/26/2023 6/26/2024
Leak Detect - Piping Aboveground N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 6/16/2022 6/16/2023
Overfill Prev Device Overfill Alarm 6/25/2021 6/25/2024
Piping Aboveground N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/9/2021 6/9/2024
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found