Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0037142 |
Illinois Power Resources Generating, LLC |
Current Owner |
12/2/2013 |
| U0031792 |
Ameren / Cilco |
Former Owner |
|
| U0002654 |
Central Illinois Light Company |
Former Owner |
|
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| N/A |
8/13/2024 |
Abandonment Log |
00859-2024ABN |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 20240551 |
Eligible |
7/30/2024
|
8/6/2024
|
$5,000
|
Letter
|
Tank Number 7
| Capacity: |
2000 |
|
Petroleum Use: |
|
| Product: |
Used Oil |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
7/21/2000 |
|
OSFM
First Notify Date: |
3/21/1986 |
|
Abandoned Material: |
|
| Current Age: |
18 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 8
| Capacity: |
10000 |
|
Petroleum Use: |
None |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Condemned Tank |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
3/21/1986 |
|
Abandoned Material: |
|
| Current Age: |
48 |
|
Abandoned Date: |
|
| Install Date: |
3/21/1978 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
2/2/2023 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Isolation Boots Flex Connector |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
6/16/2022 |
6/16/2023 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350j with CSLD |
6/16/2022 |
6/16/2023 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
6/9/2021 |
6/9/2024 |
|
Piping
|
Fiberglass Double Wall Ameron |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
6/9/2021 |
6/9/2024 |
Leak Detect - Piping
|
Sump Sensor |
6/9/2021 |
6/9/2024 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
6/9/2021 |
6/9/2024 |
|
Tank
|
Fiberglass Single Wall Owens Corning |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 9
| Capacity: |
20000 |
|
Petroleum Use: |
None |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Abandoned in place |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
3/24/2008 |
|
Abandoned Material: |
Inert material mixed with portland cement |
| Current Age: |
58 |
|
Abandoned Date: |
8/13/2024 |
| Install Date: |
12/1/1967 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
1/24/2023 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Other Aboveground Piping |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
6/26/2023 |
6/26/2024 |
|
Leak Detect - Piping
|
Aboveground |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
European with No Test Req Suction |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD |
6/16/2022 |
6/16/2023 |
|
Overfill Prev Device
|
Overfill Alarm |
6/25/2021 |
6/25/2024 |
|
Piping
|
Aboveground |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
6/9/2021 |
6/9/2024 |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Not Installed UDC Sump |
Not applicable
|
Not applicable
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Not Installed UDC Sump |
Not applicable
|
Not applicable
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found