Information
JB Pritzker, Governor
Michele L Pankow, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
3017699
Status:
Active
Facility Name:
Hari Om 1, Inc.
Address:
831 South Main Monmouth, IL 61462
County:
Warren
Property Parcel:
09-260-043-00
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
AA01365
Green Tag Issue Date:
11/4/2025
Green Tag Expiration Date:
12/31/2027
Owner Details
Owner Name:
Monmouth Investments, LLC
Owner Address:
831 S. Main Street Monmouth, IL 61462
Owner Status:
Current Owner
Purchase Date:
4/11/2024
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
8/13/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
11/4/2025
12/31/2027
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0041188
Monmouth Investments, LLC
Current Owner
4/11/2024
U0002560
Casey's Retail Company
Former Owner
3/5/2003
U0004417
Dynamic Investments Inc
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
03-0293
Eligible
6/13/2003
7/14/2003
$10,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
10000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
2/17/1987
Abandoned Material:
Current Age:
40
Abandoned Date:
Install Date:
1/1/1985
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
1/1/1985
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
8/23/2025
8/23/2026
Overfill Prev Device
Overfill Drop Tube Valve
12/12/2023
12/12/2026
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
12/12/2023
12/12/2026
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
6000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
2/17/1987
Abandoned Material:
Current Age:
40
Abandoned Date:
Install Date:
1/1/1985
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
1/1/1985
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
8/23/2025
8/23/2026
Overfill Prev Device
Overfill Drop Tube Valve
12/12/2023
12/12/2026
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
12/12/2023
12/12/2026
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found