Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3013414
Status: Closed
Facility Name: Casey's General Store #2935
Address: 885 N. Main Street
Canton, IL 61520
County: Fulton
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: U000458
Green Tag Issue Date: 2/3/2020
Green Tag Expiration Date: 7/8/2020

Owner Details

Owner Name: Casey's Retail Company
Owner Address: 3305 SE Delaware Ave.
P.O. Box 3004
Ankeny, IA 50021
Owner Status: Current Owner
Purchase Date: 11/15/2010
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/27/2020

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/3/2020 12/31/2021

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0002560 Casey's Retail Company Current Owner 11/15/2010
U0006490 Harper Oil Company Former Owner 4/1/1993
U0007764 Jacobus Oil Co Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
20-0511 6/16/2020 Removal Log 00664-2020REM
20-0511 6/17/2020 Removal Log 00664-2020REM
92-3530 4/26/1993 Removal Log
92-3530 8/20/1993 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
92-3530 Eligible 11/10/1993 12/6/1993 $15,000
20200511 Eligible 9/25/2020 9/25/2020 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8300 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/26/1993
OSFM First Notify Date: 3/1/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: 1/1/1991 Fee Due: $0.00
Product Date: 1/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8300 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/26/1993
OSFM First Notify Date: 3/1/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: 1/1/1991 Fee Due: $0.00
Product Date: 1/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8300 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/26/1993
OSFM First Notify Date: 3/1/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: 1/1/1991 Fee Due: $0.00
Product Date: 1/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 560 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/20/1993
OSFM First Notify Date: 5/14/1993 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/1/1972 Red Tag Issue Date:
Last Used Date: 1/1/1991 Fee Due: $0.00
Product Date: 1/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: E15 CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/17/2020
OSFM First Notify Date: 9/16/1993 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 8/20/1993 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/20/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/11/2020 3/11/2021
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 3/11/2020 3/11/2021
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/11/2020 3/11/2021
Overfill Prev Device Overfill Drop Tube Valve 4/5/2018 4/5/2021
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 12/9/2019 12/9/2022
Leak Detect - Piping Sump Sensor 3/11/2020 3/11/2021
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/18/2020 1/18/2023
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 10/15/2010
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 10/15/2010



Tank Number 6

Capacity: 8000 Petroleum Use:
Product: Gasoline - Non Ethanol CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/16/2020
OSFM First Notify Date: 9/16/1993 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 8/20/1993 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/20/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/11/2020 3/11/2021
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 3/11/2020 3/11/2021
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/11/2020 3/11/2021
Overfill Prev Device Overfill Drop Tube Valve 4/5/2018 4/5/2021
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 12/9/2019 12/9/2022
Leak Detect - Piping Sump Sensor 3/11/2020 3/11/2021
Piping Single Wall Transition Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/18/2020 1/18/2023
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 10/15/2010
Leak Detect - Piping Non-Discriminating Sump Sensor Sensor Functional Pass 10/15/2010

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found