Information
JB Pritzker, Governor
Michele L Pankow, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
3007216
Status:
Closed
Facility Name:
Satwinder Singh & Amandeep Singh
Address:
335 Cole Street Bushnell, IL 61422
County:
McDonough
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
P000794
Green Tag Issue Date:
4/23/2014
Green Tag Expiration Date:
12/31/2016
Owner Details
Owner Name:
A & S Real Estate Holdings, LLC
Owner Address:
108 W. Main Street Augusta, IL 62311
Owner Status:
Current Owner
Purchase Date:
9/30/2015
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
11/23/2016
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
4/23/2014
12/31/2016
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0038042
A & S Real Estate Holdings, LLC
Current Owner
9/30/2015
U0037931
J & H Real Estate Holdings, LLC
Former Owner
7/31/2015
U0015560
Uselton Oil Company, Inc.
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
16-0678
9/8/2016
Removal Log
00983-2016REM
16-0678
9/9/2016
Removal Log
00983-2016REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
20160678
Eligible
9/29/2016
9/29/2016
$5,000
Letter
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
8000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/8/2016
OSFM
First Notify Date:
4/28/1986
Abandoned Material:
Current Age:
24
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
10/1/2015
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
10/25/2013
10/25/2014
Corrosion Prot - Tank
Impressed Current Cathodic Protection
10/25/2013
10/25/2014
Corrosion Prot - Tank
Lining Materials Internal
10/10/2013
10/10/2018
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
10/25/2013
10/25/2014
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device
Overfill Alarm
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
8200
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/8/2016
OSFM
First Notify Date:
4/28/1986
Abandoned Material:
Current Age:
27
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
10/1/2015
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
10/25/2013
10/25/2014
Corrosion Prot - Tank
Impressed Current Cathodic Protection
10/25/2013
10/25/2014
Corrosion Prot - Tank
Lining Materials Internal
10/10/2013
10/10/2018
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
10/25/2013
10/25/2014
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device
Overfill Alarm
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
4000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/9/2016
OSFM
First Notify Date:
4/28/1986
Abandoned Material:
Current Age:
32
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
10/1/2015
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
10/25/2013
10/25/2014
Corrosion Prot - Tank
Impressed Current Cathodic Protection
10/25/2013
10/25/2014
Corrosion Prot - Tank
Lining Materials Internal
10/10/2013
10/10/2018
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
10/25/2013
10/25/2014
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device
Overfill Alarm
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
4000
Petroleum Use:
Product:
Kerosene
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/9/2016
OSFM
First Notify Date:
4/28/1986
Abandoned Material:
Current Age:
32
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
10/1/2015
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
10/25/2013
10/25/2014
Corrosion Prot - Tank
Impressed Current Cathodic Protection
10/25/2013
10/25/2014
Corrosion Prot - Tank
Lining Materials Internal
10/10/2013
10/10/2018
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device
Overfill Alarm
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found