Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3007159
Status: Active
Facility Name: Circle K #1418
Address: 501 North Henderson Galesburg, IL 61401
County: Knox
Property Parcel: 99-10-301-026
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001608
Green Tag Issue Date: 11/29/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Mac's Convenience Stores, LLC
Owner Address: 1100 Situs Court, Suite 100 Raleigh, NC 27606
Owner Status: Current Owner
Purchase Date: 10/10/2014
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 1/26/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 11/29/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030949 Mac's Convenience Stores, LLC Current Owner 10/10/2014
U0022245 Russell Stewart Oil Co Former Owner 12/23/1993
U0022438 Marathon Petroleum Co, LLC Former Owner 12/31/1967
U0013268 Tri-Star Marketing, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252652 (Pending)    Issue Date: 10/7/2025    Expiration Date: 12/6/2025    View NOV Form

Tanks Violations
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
3, 4, 5 Document that emergency shut-off (shear valves) are in proper working order
Facility Electrical Does Not Comply - Electrical conduit seal offs are not properly filled. Fill those empty seal offs with appropriate sealing material. Tanks # 3 & Tank #4 ATG risers.
Facility Missing copies of Annual Walkthrough Inspection Report.

NOV Number: E0020252653 (Pending)    Issue Date: 10/7/2025    Expiration Date: 12/6/2025    View NOV Form

Tanks Violations
Facility Miscellaneous - Section 175.210 Attended Self-Service Motor Fuel Dispensing Facilities and Islands All emergency stops are to be indicated by a sign that reads “EMERGENCY STOP” in at least 2-inch red capital letters.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
91-2182 8/6/1991 Removal Log 9702

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
91-2182 Eligible 12/11/2014 12/15/2014 $10,000
91-2182 Eligible 5/11/2015 6/3/2015 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/1/1991
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 8/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/1/1991
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 8/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/16/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/12/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/12/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/21/2025 3/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/21/2025 3/21/2026
Overfill Prev Device Overfill Drop Tube Valve 4/19/2024 4/19/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 5/19/2025 5/19/2028
Leak Detect - Piping Sump Sensor 3/21/2025 3/21/2026
Spill Contain Device Double Wall Spill Bucket 4/19/2024 4/19/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 3/21/2025



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/16/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/12/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/12/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/21/2025 3/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/21/2025 3/21/2026
Overfill Prev Device Overfill Drop Tube Valve 4/19/2024 4/19/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 2/25/2025 2/25/2028
Leak Detect - Piping Non-Discriminating Sump Sensor 7/18/2019 7/18/2020
Leak Detect - Piping Sump Sensor 3/21/2025 3/21/2026
Spill Contain Device Double Wall Spill Bucket 4/19/2024 4/19/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 3/21/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/28/2019



Tank Number 5

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/16/1991 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/12/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/12/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/21/2025 3/21/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 3/21/2025 3/21/2026
Overfill Prev Device Overfill Drop Tube Valve 4/19/2024 4/19/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 2/25/2025 2/25/2028
Leak Detect - Piping Sump Sensor 3/21/2025 3/21/2026
Spill Contain Device Double Wall Spill Bucket 4/19/2024 4/19/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 3/21/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found