Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3006317
Status: Closed
Facility Name: Cedar Creek, LLC
Address: 510 E. 3rd Street
Milan, IL 61264
County: Rock Island
Property Parcel: 454321556
Facility Type: Port District
Owner Type: Private
Green Tag Decal: T003247
Green Tag Issue Date: 5/2/2018
Green Tag Expiration Date: 12/31/2020

Owner Details

Owner Name: Cedar Creek, LLC
Owner Address: 450 N. MacArthur
Oklahoma City, OK 73127
Owner Status: Current Owner
Purchase Date: 6/13/2014
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/22/2021

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 9/22/2020 12/31/2022

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037338 Cedar Creek, LLC Current Owner 6/13/2014
U0012884 Roberts & Dybdahl, Inc. Former Owner 1/1/1985

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/10/2021
OSFM First Notify Date: 3/24/1986 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1985

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 1/8/2018 1/8/2021
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/5/2019 4/5/2020
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr. 12/20/2019 5/4/2020
Overfill Prev Device Overfill Alarm 12/20/2019 5/4/2020
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Field Constructed
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 5/4/2020
Tank STIP3 Single Wall Precision Test (Tank) Pass 7/20/2020

Dispenser Information



Name\ID DSL

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found